OBJECTIVES

Trigger finger is frequently treated with tendon sheath injections. This cadaveric study evaluated the accuracy and safety of blind and sonographically guided tendon sheath injections. To our knowledge, a study that precisely mapped the locations of material injected into the tendon sheath has not been reported previously.

METHODS

A total of 40 fingers (excluding thumbs) of 5 fresh cadavers were used. Methylene blue dye was injected into the flexor tendon sheath using either a blind or sonographically guided injection technique (20 fingers for each technique). The location of the dye was then determined via dissection.

RESULTS

Dye was observed only in the tendon sheath (ie, optimal outcome) in 70% of sonographically guided injections and 15% of blind injections (P = .001). Dye was observed in the tendon proper (ie, unsafe outcome) in 30% of blind injections and 0% of sonographically guided injections (P = .02).

CONCLUSIONS

We found that sonographically guided tendon sheath injections were more accurate and may be potentially safer than blind injections. These findings suggest that sonographically guided injections should be considered over blind injections when treating trigger finger.

Для цитирования: Lee Dae-Hee, Han Seung-Beom, Park Jong-Woong, Lee Soon-Hyuck, Kim Kwan-Woo, Jeong Woong-Kyo. Sonographically guided tendon sheath injections are more accurate than blind injections: implications for trigger finger treatment.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2011. DOI: 10.7863/jum.2011.30.2.197.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.