BACKGROUND

Distal radius fractures are among the most common orthopedic injuries requiring effective pain management during closed reduction. While the hematoma block is widely used, circumferential block has been proposed as an alternative due to its broader analgesic coverage. However, direct comparative evidence remains limited.

METHODS

This double-blind randomized controlled trial (RCT) included 51 patients with distal radius fractures treated from June 2023 to May 2024. Patients were randomized into hematoma block or circumferential block groups. Pain levels were measured using the Visual Analog Scale (VAS) at four time points: before injection, 5 min post-injection, during reduction, and 10 min post-reduction. Radiographic alignment and complications were also assessed.

RESULTS

Baseline characteristics were comparable between groups (p = 0.42). Pain scores were significantly lower in the circumferential block group across all post-injection time points (p < 0.01). VAS scores: Circumferential block provided better pain relief at 5 min post-injection (1.19 vs. 3.08), during reduction (1.61 vs. 4.96), and 10 min post-reduction (1.50 vs. 4.12). Radiographic alignment outcomes were similar between groups. No adverse events (e.g., neurovascular injury, infection) were reported.

CONCLUSIONS

Circumferential block demonstrated superior pain control compared to hematoma block without compromising fracture alignment or increasing complications. Its broader periosteal innervation coverage and ease of administration suggest it may be a valuable alternative for pain management in distal radius fracture reduction. However, further studies with larger sample sizes and long-term functional assessments are warranted to confirm these findings.

LEVEL OF EVIDENCE I: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Для цитирования: Kalapukdee Natee, Inthawong Patarapon, Vechasilp Jaruwat, Nitiwarangkul Lertkong, Jaroenporn Woraphon. Comparative Efficacy of Hematoma Block Versus Circumferential Block in Pain Management for Distal Radius Fracture Reduction.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2026. DOI: 10.1007/s00590-026-04733-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.