Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation.

Lee Jae Chul, Jang Hae-Dong, Choi Sung-Woo, Shin Byung-Joon

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To evaluate the accuracy of percutaneous pedicle screw (PPS) insertion in degenerative lumbar disease treated with minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) and to analyze risk factors and long-term clinical outcomes of screw violation.

METHODS

Sixty-two consecutive patients (262 screws) were included. Based on postoperative computed tomography (CT) axial images, a PPS that perforated out of the pedicle was classified into a violation group, while screws surrounded by pedicular cortical bone were classified into a correct group. A logistic regression model was used for risk factor analysis of violation. We also observed the long-term clinical outcomes using the Oswestry disability index and visual analog scale.

RESULTS

Of the 262 screws, 14 (5.3%) were considered to be violated (10 medial violations and 4 lateral violations). All violations of S1 and L5 were in the medial direction. In contrast, entire violations of L4 were always lateral and of the 2 violations of L3, one was lateral and the other was medial. There were no cases of superior or inferior violation. The mean pedicle convergence angle (CA) was significantly higher in the violation group (mean ± standard deviation, 27.0° ± 6.2°) than in the correct group (21.7° ± 5.4°). There were no significant differences according to vertebral rotational angle, body mass index, bone mineral density, and surgical timing (learning curve) between the two groups. Logistic regression analyses demonstrated that a high CA was a significant risk factor for pedicle wall violation (p = 0.002). There were no significant differences in clinical or radiographic results between the two groups in 60 patients who were followed up for more than 1 year and in 40 patients who were followed up for more than 5 years. There were 2 patients who required reoperation to replace a screw due to leg pain.

CONCLUSIONS

With PPS insertion during MI-TLIF, the rate of pedicle violation was 5.3% (14/262). An understanding of the anatomical characteristics of each vertebra and the unique structures of the patient is essential to prevent pedicle violations. Even in the violation group, PPS fixation was found to be a safe and useful procedure with successful long-term radiographic and clinical outcomes.

Для цитирования: Lee Jae Chul, Jang Hae-Dong, Choi Sung-Woo, Shin Byung-Joon. Computed Tomography Evaluation of Percutaneous Pedicle Screws Inserted during Minimally Invasive Transforaminal Lumbar Interbody Fusion: Long-term Follow-up Results of Screw Violation.. Clinics in orthopedic surgery. 2022. DOI: 10.4055/cios21229.