MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0329710

Медицинская библиотека · PloS one · 2025

Differences in stiffness across the patellar tendon: An observational study using tendotonometry.

van Dam Lotte, Terink Rieneke, van den Akker-Scheek Inge, Zwerver Johannes

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

Patellar tendinopathy is an injury with pain mostly located at the proximal region of the tendon and possibly related to changes in patellar tendon (PT) stiffness. However, little is known about the stiffness at different locations within the PT and the reliability of measuring stiffness at these locations. Therefore, the aim of this study was to investigate the difference in PT stiffness and reliability of its measurement at different PT locations in non-injured male (n = 24) and female (n = 24) recreational athletes. Tendotonometry was performed in triplet at nine locations on the PT of the dominant leg (proximal, horizontal-midline (HM) and distal, at all three levels: medial, vertical-midline (VM) and lateral) in 90 degrees knee flexion in the resting position. Both in males and females, PT stiffness was higher proximal and distal compared to HM and lower medial and lateral compared to VM. PT stiffness ranged from 702.3 ± 124.6N/m to 882.6 ± 117.7N/m for females and 822.6 ± 124.7N/m to 990.3 ± 141.0N/m for males. With respect to reliability, the intraclass correlation coefficient was above 0.9, and the coefficient of variation was below 3% at all nine measurement locations, indicating excellent reliability. In conclusion, PT stiffness is higher at the proximal and distal part of the tendon compared to HM, and lower at the medial and lateral part of the tendon compared to VM. Tendotonometry can reliably be used to measure PT stiffness at different locations on the tendon.

Для цитирования: van Dam Lotte, Terink Rieneke, van den Akker-Scheek Inge, Zwerver Johannes. Differences in stiffness across the patellar tendon: An observational study using tendotonometry.. PloS one. 2025. DOI: 10.1371/journal.pone.0329710.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.