MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/03635465231157430

Медицинская библиотека · The American journal of sports medicine · 2023

Distal Clavicle Autograft Versus Traditional and Congruent Arc Latarjet Procedures: A Comparison of Surface Area and Glenoid Apposition With 3-Dimensional Computed Tomography and 3-Dimensional Magnetic Resonance Imaging.

Kim Billy I, Hudson Caroline P, Taylor Dean C, Anakwenze Oke, Dickens Jonathan F, Lau Brian C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Limited studies have compared graft-glenoid apposition and glenoid augmentation area between the Latarjet procedure and distal clavicle graft in glenohumeral stabilization. Additionally, preoperative planning is typically performed using computed tomography (CT), and few studies have used 3-dimensional (3D) magnetic resonance imaging (MRI) reformations to assess graft dimensions.

PURPOSE: The purpose of this study was 2-fold: (1) to compare bony apposition, glenoid augmentation, and graft width among coracoid and distal clavicle bony augmentation techniques and (2) to determine the viability of 3D MRI to assess bone graft dimensions.

STUDY

DESIGN

Controlled laboratory study.

METHODS

A total of 24 patients with recurrent glenohumeral instability and bone loss were included in this study. 3D CT and 3D MRI reformations were utilized to measure pertinent dimensions for 5 orientations of coracoid and distal clavicle autografts: (1) standard Latarjet procedure (SLJ), (2) congruent arc Latarjet procedure (CLJ), (3) distal clavicle attached by its posterior surface (DCP), (4) distal clavicle attached by its inferior surface (DCI), and (5) distal clavicle attached by its resected end (DCR). Glenoid augmentation was defined as the graft surface area contributing to the glenoid. Bone-on-bone apposition was defined as the graft-glenoid contact area for bone healing potential, and graft width was pertinent for fixation technique. Glenoid bone loss ranged from 0% to 34%. Paired t tests were used to compare graft sizes between patients and compare 3D CT versus 3D MRI measurements.

RESULTS

The CLJ had the largest graft surface area (mean, 318.41 ± 74.44 mm2), while the SLJ displayed the most bone-on-bone apposition (mean, 318.41 ± 74.44 mm2). The DCI had the largest graft width (mean, 20.62 ± 3.93 mm). Paired t tests revealed no significant differences between the Latarjet techniques, whereas distal clavicle grafts varied significantly with orientation. All 3D CT and 3D MRI measurements were within 1 mm of each other, and only 2 demonstrated a statistically significant difference (coracoid width: 13.03 vs 13.98 mm, respectively [P = .010]; distal clavicle thickness: 9.69 vs 10.77 mm, respectively [P = .002]). 3D CT and 3D MRI measurements demonstrated a strong positive correlation (r > 0.6 and P < .001 for all dimensions).

CONCLUSION

Glenoid augmentation, bony apposition, and graft width varied with coracoid or distal clavicle graft type and orientation. Differences between 3D CT and 3D MRI were small and likely not clinically significant.

CLINICAL RELEVANCE: 3D MRI is a viable method for preoperative planning and graft selection in glenoid bone loss.

Для цитирования: Kim Billy I, Hudson Caroline P, Taylor Dean C, Anakwenze Oke, Dickens Jonathan F, Lau Brian C. Distal Clavicle Autograft Versus Traditional and Congruent Arc Latarjet Procedures: A Comparison of Surface Area and Glenoid Apposition With 3-Dimensional Computed Tomography and 3-Dimensional Magnetic Resonance Imaging.. The American journal of sports medicine. 2023. DOI: 10.1177/03635465231157430.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.