MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/brs.0b013e3181bde562

Медицинская библиотека · Spine · 2010

Change in Modic type 1 and 2 signals after posterolateral fusion surgery.

Ohtori Seiji, Yamashita Masaomi, Yamauchi Kazuyo, Inoue Gen, Koshi Takana, Suzuki Munetaka, Orita Sumihisa, Eguchi Yawara, Ochiai Nobuyasu, Kishida Shunji, Takaso Masashi, Kuniyoshi Kazuki, Ishikawa Tetsuhiro, Arai Gen, Miyagi Masayuki, Kamoda Hiroto, Nakamura Junichi, Aoki Yasuchika, Takahashi Kazuhisa

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Prospective cohort study.

OBJECTIVE

To examine the change of Modic Type 1 to Type 2 after posterolateral fusion surgery.

SUMMARY OF BACKGROUND DATA: Lumbar vertebral bone marrow change is divided into Modic types. Magnetic resonance imaging reveals Modic Type 1 and 2 signals. Some reports indicate that with time, Type 1 signals (intervertebral instability) change to Type 2 (restabilization), but the reliability of this assertion is unclear. The current study examines the change of Modic Type 1 signals to Type 2 after posterolateral fusion surgery.

METHODS

Patients with Modic Type 1 and 2 signals were selected (mean age, 65 years). All patients suffered low back pain and leg pain due to lumbar spinal canal stenosis, and underwent decompression and posterolateral fusion surgery. We evaluated change in Modic signal and severity of low back pain (Visual analogue scale score, Japanese Orthopedic Association score, and Oswestry Disability Index before and 24 months after surgery.

RESULTS

Of 21 patients with Modic Type 1 signals before surgery, 2 cases changed to normal bone marrow, 9 to Type 2, and 12 remained Type 1. Of 12 patients with Type 2 signals, none changed to Type 1, 2 changed to normal bone marrow, and 10 remained Type 2. Visual analogue scale score, Japanese Orthopedic Association score, and Oswestry Disability Index improved after surgery; however, low back pain was not significantly associated with signal change after surgery (P > 0.05).

CONCLUSION

In the current study, Modic Type 1 signals changed to Type 2; however, Type 2 did not change to Type 1, suggesting that Type 2 signals indicate a stabilized stage. For Modic Type 1 and 2 signals, there were changes to normal bone marrow signals in 4 cases. Therefore, degenerated bone marrow may be able to regenerate after surgical stabilization. We did not show a significant difference between low back pain and signal type.

Для цитирования: Ohtori Seiji, Yamashita Masaomi, Yamauchi Kazuyo, Inoue Gen, Koshi Takana, Suzuki Munetaka, Orita Sumihisa, Eguchi Yawara, Ochiai Nobuyasu, Kishida Shunji, Takaso Masashi, Kuniyoshi Kazuki, Ishikawa Tetsuhiro, Arai Gen, Miyagi Masayuki, Kamoda Hiroto, Nakamura Junichi, Aoki Yasuchika, Takahashi Kazuhisa. Change in Modic type 1 and 2 signals after posterolateral fusion surgery.. Spine. 2010. DOI: 10.1097/brs.0b013e3181bde562.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.