MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00256-023-04365-w

Медицинская библиотека · Skeletal radiology · 2023

Interreader reliability assessment of hallux valgus evaluation on dorsoplantar weightbearing radiographs from a prospective multi-center trial and correlation with patient-reported outcome measures.

Ramachandran Shyam S, Reine Seth, Archer Holden, Koay Jennifer, Wukich Dane K, Chhabra Avneesh

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To determine inter-reader reliability (IRR) of hallux valgus (HV) related parameters, i.e. intermetatarsal angle (IMA), hallux valgus angle (HVA), lateral round sign of the first metatarsal, tibial sesamoid position (TSP), metatarsus adductus angle (MAA), transverse osseous foot width, 1st MT length, MTP osteoarthritis (OA), and distal metatarsal articular angle (DMAA). These were correlated with patient-reported outcome measures (PROMs).

MATERIALS AND

METHODS

A prospective single-arm Level 3 multicenter clinical trial in which standardized radiographs and PROMs were collected at the time of the initial patient visit for pre-operative assessment. Two musculoskeletal radiologists performed measurements blinded to each other's reads and clinical information. Intraclass coefficient and kappa were obtained for inter-reader analysis. A partial spearman rank order was used to correlate the measurements with PROMs.

RESULTS

The final cohort size of 183 patients had mean age of 40.77 years, mean body mass index was 26.11 kg/m2, with 91.2% females and 8.7% males. There was excellent IRR for HVA (0.96, CI: [0.94,0.97]), IMA (0.92, CI: [0.89,0.94]), transverse osseous foot width (0.99, CI: [0.98,1.00]), and DMAA (0.80, CI: [0.74, 0.85]), good agreement for TSP (0.73, CI:[0.67,0.79]) and MAA (0.67, CI: [0.16, 0.84]), fair agreement for MTP OA (0.48, CI: [0.36,0.59]), and poor agreement for lateral round sign (0.32, CI: [0.11, 0.52]. The negative correlation of increasing transverse osseous foot width with worsening PROMIS physical but better MOxFQ and VAS scores is likely spurious.

CONCLUSION

Good to excellent inter-reader reliability was observed for the most often used measurements for HV assessment without major trends in their correlations with PROMs. Lateral round sign is not a reliable finding in HV deformity.

Для цитирования: Ramachandran Shyam S, Reine Seth, Archer Holden, Koay Jennifer, Wukich Dane K, Chhabra Avneesh. Interreader reliability assessment of hallux valgus evaluation on dorsoplantar weightbearing radiographs from a prospective multi-center trial and correlation with patient-reported outcome measures.. Skeletal radiology. 2023. DOI: 10.1007/s00256-023-04365-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.