MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/oi9.0000000000000415

Медицинская библиотека · OTA international : the open access journal of orthopaedic trauma · 2025

Osseous union after antibiotic cement application with retention of stable orthopaedic hardware in fracture-related infections without union.

Mansour Devone, Ross Hunter, Court Tannor, Cavazos Daniel, VanAken Trey D, Vaidya Rahul

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate treatment outcomes of patients treated with antibiotic impregnated cement applied over implanted orthopaedic hardware, in the setting of fracture-related infection, without osseous union, after open reduction internal fixation.

DESIGN

Retrospective observational case series.

SETTING

Level 1 trauma center.

PATIENTS/

PARTICIPANTS

Retrospective review of 15 patients who underwent antibiotic cement application to their retained plate for the treatment of acute fracture-related infections (12) and acutely infected nonunion (3) status after open reduction internal fixation (ORIF).

OUTCOMES: Suppression of infection and radiographic union by final follow-up.

RESULTS

Antibiotic plate application successfully led to fracture union in all 15 patients (100%). Three of these patients (20%) required removal of hardware. Of these 3 patients, all 3 achieved fracture union before hardware removal. However, 2 of these patients developed a chronic infection and were placed on long term PO antibiotics for chronic infection suppression, thus making them ineligible for classification as free of infection.

CONCLUSIONS

The results of this study suggest that application of antibiotic cement to retained plates/screws for ORIF during treatment of both acute fracture infections and acutely infected nonunions is a viable technique to achieve osseous union. Hardware removal may be required in some cases. Use of this technique supports fracture healing and local infection control, while maintaining construct stability long enough to achieve fracture union.

Для цитирования: Mansour Devone, Ross Hunter, Court Tannor, Cavazos Daniel, VanAken Trey D, Vaidya Rahul. Osseous union after antibiotic cement application with retention of stable orthopaedic hardware in fracture-related infections without union.. OTA international : the open access journal of orthopaedic trauma. 2025. DOI: 10.1097/oi9.0000000000000415.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.