MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-023-06448-0

Медицинская библиотека · BMC musculoskeletal disorders · 2023

Postoperative clinical outcomes for kinematically, restricted kinematically, or mechanically aligned total knee arthroplasty: a systematic review and network meta-analysis of randomized controlled trials.

Miura Takanori, Takahashi Tsuneari, Watanabe Jun, Kataoka Yuki, Ae Ryusuke, Saito Hidetomo, Takeshita Katsushi, Miyakoshi Naohisa

Систематический обзорСтатьяNetwork Meta-AnalysisПеревод в очереди

Аннотация

BACKGROUND

Mechanically aligned total knee arthroplasty (MATKA) is a well-established procedure. Kinematically aligned TKA (KATKA) has been proposed to restore and preserve pre-arthritic knee anatomy. However, normal knee anatomy varies widely, and there have been concerns regarding restoring unusual anatomy. Accordingly, restricted KATKA (rKATKA) was introduced to reproduce constitutional knee anatomy within a safe range. This network meta-analysis (NMA) aimed to evaluate the clinical and radiological outcomes of the surgeries.

METHODS

We performed a database search on August 20, 2022, which included randomized controlled trials (RCTs) comparing any two of the three surgical TKA techniques for knee osteoarthritis. We conducted a random-effects NMA within the frequentist framework and evaluated confidence in each outcome using the Confidence in Network Meta-Analysis tool.

RESULTS

Ten RCTs with 1,008 knees and a median follow-up period of 1.5 years were included. The three methods might result in little to no difference in range of motion (ROM) between methods. In patient-reported outcome measures (PROMs), the KATKA might result in a slight improvement compared with the MATKA (standardized mean difference, 0.47; 95% confidence interval [CI], 0.16-0.78; very low confidence). There was little to no difference in revision risk between MATKA and KATKA. KATKA and rKATKA showed a slight valgus femoral component (mean difference [MD], -1.35; 95% CI, -1.95-[-0.75]; very low confidence; and MD, -1.72; 95% CI, -2.63-[-0.81]; very low confidence, respectively) and a slight varus tibial component (MD, 2.23; 95% CI, 1.22-3.24; very low confidence; and MD, 1.25; 95% CI, 0.01-2.49; very low confidence, respectively) compared with MATKA. Tibial component inclination and hip-knee-ankle angle might result in little to no difference between the three procedures.

CONCLUSIONS

KATKA and rKATKA showed similar ROM and PROMs and a slight variation in the coronal component alignment compared with MATKA. KATKA and rKATKA are acceptable methods in short- to mid-term follow-up periods. However, long-term clinical results in patients with severe varus deformity are still lacking. Surgeons should choose surgical procedures carefully. Further trials are warranted to evaluate the efficacy, safety, and subsequent revision risk.

Для цитирования: Miura Takanori, Takahashi Tsuneari, Watanabe Jun, Kataoka Yuki, Ae Ryusuke, Saito Hidetomo, Takeshita Katsushi, Miyakoshi Naohisa. Postoperative clinical outcomes for kinematically, restricted kinematically, or mechanically aligned total knee arthroplasty: a systematic review and network meta-analysis of randomized controlled trials.. BMC musculoskeletal disorders. 2023. DOI: 10.1186/s12891-023-06448-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.