DOI 10.1186/s12891-023-07142-x
Limited value of platelet-related markers in diagnosing periprosthetic joint infection.
Аннотация
OBJECTIVE
To evaluate the diagnostic values of serum platelet count (PC), mean platelet volume ratio (MPV), platelet count to mean platelet volume ratio (PVR), platelet to lymphocyte ratio (PLR), platelet to neutrophil ratio (PNR), PC/Albumin-globulin ratio (PC/AGR), and PC/C-reactive protein (PC/ CRP) in the diagnosis of periprosthetic joint infection (PJI).
METHODS
The medical records were retrospectively analyzed of the 158 patients who had undergone hip or knee revisions from January 2018 to May 2022. Of them, 79 cases were diagnosed with PJI and 79 with aseptic loosening (AL). PJI was defined using the Musculoskeletal Infection Society criteria. The plasma levels of CRP, the erythrocyte sedimentation rate (ESR), PC, MPV, PVR, PLR, PNR, PC/AGR, and PC/CRP in the 2 groups were recorded and analyzed. In addition, tests were performed according to different joint types. The receiver operating characteristic curve was used to calculate the sensitivity and specificity of each indicator. The diagnostic value for each indicator was calculated according to the area under the curve (AUC).
RESULTS
The PC, PVR, PLR and PC/AGR levels in the PJI group were significantly higher than those in the AL group, while PC/CRP levels were significantly lower (P < 0.001). The AUC for PC/CRP, and PC/AGR was 0.804 and 0.802, respectively, which were slightly lower than that of CRP (0.826) and ESR (0.846). ROC analysis for PC/CRP, and PC/AGR revealed a cut-off value of 37.80 and 160.63, respectively, which provided a sensitivity of 73.42% and 84.81% and a specificity of 75.95% and 65.82% for PJI. The area under the curve of PLR and PC was 0.738 and 0.702. The area under the curve values for PVR, PNR, and MPV were 0.672, 0.553, and 0.544, respectively.
CONCLUSIONS
The results of this study suggest that PC, PLR, PC/CRP, and PC/AGR values do not offer significant advantages over ESR or CRP values when employed for the diagnosis of PJI. PVR, PNR, and MPV were not reliable in the diagnosis of PJI.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.