PURPOSE: Little is known about the perioperative characteristics associated with a posterior spinal fusion (PSF) in adolescent idiopathic scoliosis patients previously treated with vertebral body tethering (VBT). We aimed to determine if operative time, estimated blood loss, postoperative length of stay, instrumentation type, and implant density differed in patients that received a PSF (i.e., PSF-Only) or a PSF following a failed VBT (i.e., PSF-VBT).

METHODS

We retrospectively assessed matched cohort data (PSF-VBT = 22; PSF-Only = 22) from two multi-center registries. We obtained: (1) operative time, (2) estimated blood loss, (3) postoperative length of stay, (4) instrumentation type, and (5) implant density. Theoretical fusion levels prior to the index procedure were obtained for PSF-VBT and compared to the actual levels fused.

RESULTS

We observed no difference in operative time, estimated blood loss, or postoperative length of stay. Instrumentation type was all-screw in PSF-Only and varied in PSF-VBT with nearly 25% of patients exhibiting a hybrid construct. There was no added benefit to removing anterior instrumentation prior to fusion; however, implant density was higher in PSF-Only (1.9 ± 0.2) than when compared to PSF-VBT (1.7 ± 0.3). An additional two levels were fused in 50% of PSF-VBT patients, most of which were added to the distal end of the construct.

CONCLUSIONS

We found that operative time, estimated blood loss, and postoperative length of stay were similar in both cohorts; however, the length of the fusion construct in PSF-VBT is likely to be two levels longer when a failed VBT is converted to a PSF.

Для цитирования: Boeyer Melanie E, Groneck Andrew, Alanay Ahmet, Neal Kevin M, Larson A Noelle, Parent Stefan, Newton Peter, Miyanji Firoz, Haber Lawrence, Harms Study Group, Hoernschemeyer Daniel G. Operative differences for posterior spinal fusion after vertebral body tethering: Are we fusing more levels in the end?. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2022. DOI: 10.1007/s00586-022-07450-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.