MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.23.00532

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2023

A Pilot Observational Study Evaluating the Diagnostic Capacity of Rotational Thromboelastometry in Periprosthetic Joint Infections.

Tsantes Andreas G, Papadopoulos Dimitrios V, Goumenos Stavros, Trikoupis Ioannis G, Tsante Konstantina A, Bellou Vanesa, Koulouvaris Panagiotis, Houhoula Dimitra, Kriebardis Anastasios, Piovani Daniele, Nikolopoulos Georgios K, Mavrogenis Andreas F, Papagelopoulos Panayiotis J, Bonovas Stefanos, Tsantes Argirios E

Наблюдательное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Periprosthetic joint infections (PJIs) are associated with altered hemostatic dynamics; therefore, coagulation laboratory methods such as rotational thromboelastometry (ROTEM) may be valuable in their diagnosis. The aim of this study was to evaluate the diagnostic role of ROTEM in PJI.

METHODS

A diagnostic study was conducted including 65 patients who underwent revision total hip arthroplasty or total knee arthroplasty due to PJI (30 patients) or aseptic loosening (35 patients). Preoperative laboratory evaluation included conventional coagulation studies, inflammatory markers, and ROTEM analysis. These parameters were compared between patients with PJI and patients with aseptic loosening.

RESULTS

Several ROTEM parameters differed in the patients with PJI, indicating a higher coagulation potential associated with PJI. Specifically, the development of PJI was associated with higher EXTEM maximum clot firmness (MCF) (odds ratio [OR], 1.12 [95% confidence interval (CI), 1.04 to 1.20]; p = 0.001). Among the ROTEM parameters, EXTEM MCF was found to have the highest diagnostic accuracy for PJI (area under the receiver operating characteristic curve, 0.850; sensitivity, 76.6%; specificity, 91.4%), which was comparable with C-reactive protein (CRP) (p = 0.22) and erythrocyte sedimentation rate (ESR) (p = 0.65), but higher than D-dimer (p = 0.037). Moreover, the combined diagnostic accuracy of elevated EXTEM MCF and CRP was improved compared with CRP alone (p = 0.019).

CONCLUSIONS

Our results indicate that ROTEM analysis might be helpful for the detection of the hemostatic derangements that are associated with the development of PJI. However, because of the small size of this pilot study, further research is needed to investigate the value of incorporating viscoelastic studies in diagnostic scores for PJI.

LEVEL OF EVIDENCE: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Tsantes Andreas G, Papadopoulos Dimitrios V, Goumenos Stavros, Trikoupis Ioannis G, Tsante Konstantina A, Bellou Vanesa, Koulouvaris Panagiotis, Houhoula Dimitra, Kriebardis Anastasios, Piovani Daniele, Nikolopoulos Georgios K, Mavrogenis Andreas F, Papagelopoulos Panayiotis J, Bonovas Stefanos, Tsantes Argirios E. A Pilot Observational Study Evaluating the Diagnostic Capacity of Rotational Thromboelastometry in Periprosthetic Joint Infections.. The Journal of bone and joint surgery. American volume. 2023. DOI: 10.2106/jbjs.23.00532.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.