Effect of Plate-Bone Distance and Screw Number on 2.0-mm Locking Construct Torsional Stiffness and Plate Strain in a Diaphyseal Fracture Gap Model.

Evans Alecia, Glyde Mark, Hosgood Giselle, Day Rob

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the effect of plate-bone distance and screw number on 2.0-mm locking compression plate (LCP) torsional stiffness and plate strain for a fixed working length in a diaphyseal fracture gap model.

STUDY

DESIGN

In vitro biomechanical study.

METHODS

The LCP was tested with nine different combinations of plate-bone distance (PBD) (1, 1.5, and 3 mm) and screw number (SN) (two, three, or four screws per fragment) across the same working length. Six replicates per group were tested. Constructs were subjected to quasi-static, non-destructive torsion producing overall construct stiffness data (Nm/degree). Plate surface strain data were recorded from three-dimensional digital image correlation during testing for all constructs.

RESULTS

A greater PBD and a low SN resulted in lower construct stiffness (p = 0.015, and P > 0.0001, respectively) in torsion. Across all PBD, there was significantly less stiffness for constructs with two screws per fragment, compared with three screws or four screws. No significant difference was detected in plate strain for any combination of PBD and SN.

CONCLUSION

In this model, incrementally increasing the PBD and decreasing the SN resulted in less construct stiffness in torsion, with marked reduction in torsional stiffness in constructs with two screws per fragment compared with three or four screws per fragment.

Для цитирования: Evans Alecia, Glyde Mark, Hosgood Giselle, Day Rob. Effect of Plate-Bone Distance and Screw Number on 2.0-mm Locking Construct Torsional Stiffness and Plate Strain in a Diaphyseal Fracture Gap Model.. Veterinary and comparative orthopaedics and traumatology : V.C.O.T. 2025. DOI: 10.1055/a-2749-6666.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.