MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/ojuffc.2025.3560585

Медицинская библиотека · IEEE open journal of ultrasonics, ferroelectrics, and frequency control · 2025

VisR Ultrasound Improves Diagnosis of Breast Cancer by the Elastogram-to-B-Mode Ratio in a Blinded Reader Study.

Phillips Anna V, Kuzmiak Cherie M, Torres Gabriela, Gallippi Caterina M

СтатьяПеревод в очереди

Аннотация

Ultrasound elastography is increasingly being used alongside mammography for breast cancer diagnosis, particularly in women with radiographically dense breasts. The elastogram-to-B-Mode ratio (E/B), which compares lesion sizes in B-Mode and stiffness images, has been shown to differentiate malignant (E/B >1) from benign (E/B <1) masses. However, the diagnostic utility of E/B has not yet been evaluated using viscosity images, despite viscosity being an emerging biomarker for malignancy. Furthermore, neglecting viscosity can confound elasticity estimation in viscoelastic media like breast tissue. To address this limitation, we used Viscoelastic Response (VisR) ultrasound to assess the diagnostic value of E/B derived from both relative stiffness (RE) and relative viscosity (RV) images. In a blinded reader study, E/B values from viscosity images exhibited similar trends (>1 in malignant lesions and <1 in benign lesions) to those observed in stiffness images. Additionally, E/B values calculated from RE alone, RV alone, or a combination of RE and RV achieved 4-16% higher AUCs for discriminating malignant lesions compared to E/B derived solely from Acoustic Radiation Force Impulse (ARFI) peak displacement. These results suggest that incorporating VisR-derived viscosity and elasticity metrics into E/B calculations could significantly improve diagnostic accuracy for breast cancer detection.

Для цитирования: Phillips Anna V, Kuzmiak Cherie M, Torres Gabriela, Gallippi Caterina M. VisR Ultrasound Improves Diagnosis of Breast Cancer by the Elastogram-to-B-Mode Ratio in a Blinded Reader Study.. IEEE open journal of ultrasonics, ferroelectrics, and frequency control. 2025. DOI: 10.1109/ojuffc.2025.3560585.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.