MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000031496

Медицинская библиотека · Medicine · 2022

Radiological evaluation of atlantoaxial fusion using C2 translaminar screws and C2 pedicle screws: Does the screw halo sign imply fusion failure?

Lee Subum, Hur Junseok W, Lee Jang-Bo, Park Jin Hoon, Park Daewon, Park Sang-Jin, Kim Kyoung-Tae, Cho Dae-Chul

СтатьяПеревод в очереди

Аннотация

The purpose of this study was to identify the criteria for atlantoaxial (AA) fusion by comparing follow-up lateral radiographs and computed tomography (CT) images. We retrospectively analyzed data from 161 consecutive patients undergoing AA fusion. Patients with a minimum of 1 year of CT follow-up after AA fusion surgery using C2 pedicle screws or translaminar screws (C2TLS) were included. Patients were followed up radiographically at 3, 6, and 12 months after surgery, and dynamic lateral radiographs were also evaluated. A total of 49 patients were analyzed, with a mean CT image follow-up of 41.6 ± 37.6 months. Thirty eight patients had C2 pedicle screw placement, and 11 patients underwent planned C2TLS. AA fusion with bridging bone mass formation was achieved in 45/49 (91.8%) patients. Screw halos were observed in 14/49 (28.6%) patients. Among them, final fusion failure occurred in 2 (14.3%) patients. The last follow-up CT showed no difference in the fusion failure rate according to the presence or absence of a screw halo (no halo, 5.7%; halo, 14.3%; P = .33). The differences in C1-2 segmental angles (SA) in flexion-extension dynamic lateral radiographs were 1.99 ± 1.62° in the fusion group and 4.37 ± 2.13° in the non-fusion group (P = .01). The likelihood of fusion failure increased when the SA gap was greater than 2.62° (P = .05). C2TLS placement had a significantly higher incidence of screw halos. However, the halo sign was not significantly related to final bone fusion. Bone fusion could be predicted when the SA gap of C1-2 was less than 2.62° on the dynamic radiograph.

Для цитирования: Lee Subum, Hur Junseok W, Lee Jang-Bo, Park Jin Hoon, Park Daewon, Park Sang-Jin, Kim Kyoung-Tae, Cho Dae-Chul. Radiological evaluation of atlantoaxial fusion using C2 translaminar screws and C2 pedicle screws: Does the screw halo sign imply fusion failure?. Medicine. 2022. DOI: 10.1097/md.0000000000031496.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.