MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-022-07440-3

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022

Mid-term efficacy and safety of Escherichia coli-derived rhBMP-2/hydroxyapatite carrier in lumbar posterolateral fusion: a randomized, multicenter study.

Cho Minjoon, You Ki-Han, Yeom Jin Sup, Kim Hyoungmin, Lee Kwang Bok, Cho Jae Hwan, Yang Jae Jun, Lee Jae Hyup

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: This study aimed to evaluate the mid-term efficacy and safety of Escherichia coli-derived bone morphogenetic protein-2 (E.BMP-2)/hydroxyapatite (HA) in lumbar posterolateral fusion (PLF).

METHODS

This multicenter, evaluator-blinded, observational study utilized prospectively collected clinical data. We enrolled 74 patients who underwent lumbar PLF and had previously participated in the BA06-CP01 clinical study, which compared the short-term outcomes of E.BMP-2 with an auto-iliac bone graft (AIBG). Radiographs and CT scans were analyzed to evaluate fusion grade at 12, 24, and 36 months. Visual analog scale (VAS), Oswestry disability index (ODI), and Short Form-36 (SF-36) scores were measured preoperatively and at 36 months after surgery. All adverse events in this study were assessed for its relationship with E.BMP-2.

RESULTS

The fusion grade of the E.BMP-2 group (4.91 ± 0.41) was superior to that of the AIBG group (4.25 ± 1.26) in CT scans at 36 months after surgery (p = 0.007). Non-union cases were 4.3% in the E.BMP-2 and 16.7% in the AIBG. Both groups showed improvement in pain VAS, ODI, and SF-36 scores when compared to the baseline values, and there were no statistically significant differences between the two groups. No treatment-related serious adverse reactions were observed in either group. No neoplasm-related adverse events occurred in the E.BMP-2 group.

CONCLUSIONS

The fusion quality of E.BMP-2/HA was superior to that of AIBG. E.BMP-2/HA showed comparable mid-term outcomes to that of AIBG in terms of efficacy and safety in one-level lumbar PLF surgery.

Для цитирования: Cho Minjoon, You Ki-Han, Yeom Jin Sup, Kim Hyoungmin, Lee Kwang Bok, Cho Jae Hwan, Yang Jae Jun, Lee Jae Hyup. Mid-term efficacy and safety of Escherichia coli-derived rhBMP-2/hydroxyapatite carrier in lumbar posterolateral fusion: a randomized, multicenter study.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2022. DOI: 10.1007/s00586-022-07440-3.