Pudendal nerve electroacupuncture for lumbar spinal canal stenosis - a case series.

Inoue Motohiro, Hojo Tatsuya, Nakajima Miwa, Kitakoji Hiroshi, Itoi Megumi, Katsumi Yasukazu

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the effectiveness of pudendal nerve electroacupuncture for lumbar and lower limb symptoms in patients with lumbar spinal canal stenosis for whom acupuncture of the lumbar and lower limb muscles had been ineffective.

METHODS

Nine patients with lumbar spinal canal stenosis for whom conventional acupuncture at the lumbar and lower limb muscles had no effect. Pudendal nerve electroacupuncture was performed eight times (once per week). VAS scores and continuous walking distance were used to evaluate changes in symptoms.

RESULTS

The following changes in symptoms occurred after pudendal nerve electroacupuncture: low back pain was improved from 45.3+/-17.4mm (mean +/- SD) to 39.2+/-14.0mm, lower limb pain was improved from 61.1+/-5.6mm to 35.4+/-11.9mm, lower limb dysaesthesia was improved from 63.9+/-8.4mm to 46.9+/-16.2mm, and continuous walking distance was improved from 100.0+/-35.4m to 250.0+/-136.9m. Conclusion Pudendal nerve electroacupuncture may be an effective treatment for lumbar and lower limb symptoms due to spinal canal stenosis, and is potentially useful in patients who have not responded to conventional acupuncture.

Для цитирования: Inoue Motohiro, Hojo Tatsuya, Nakajima Miwa, Kitakoji Hiroshi, Itoi Megumi, Katsumi Yasukazu. Pudendal nerve electroacupuncture for lumbar spinal canal stenosis - a case series.. Acupuncture in medicine : journal of the British Medical Acupuncture Society. 2008. DOI: 10.1136/aim.26.3.140.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.