MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2023.08.073

Медицинская библиотека · The Journal of arthroplasty · 2023

Can the Current Thresholds for Synovial Cell Count and Neutrophil Percentage to Diagnose Prosthetic Joint Infection be Applied to Metal-on-Metal Rotating Hinge Total Knee Arthroplasty?

Theil Christoph, Moellenbeck Burkhard, Schwarze Jan, Puetzler Jan, Klingebiel Sebastian, Bockholt Sebastian, Gosheger Georg

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Synovial leukocyte count analysis is an important tool in the diagnosis of PJI. However, results can be poor if metallosis is present. The issue of metallosis was established for some rotating hinge knee arthroplasty designs.

METHODS

This was a retrospective single-center analysis that included 108 patients who had a single-design metal-on-metal rotating hinge knee arthroplasty who underwent revision surgery and had prior synovial fluid analysis performed. The diagnostic accuracy of leukocyte count and the percentage of polymorphonuclear neutrophiles (% PMN) were investigated.

RESULTS

Patients who had a PJI had a higher median leukocyte count and % PMN compared to aseptic revisions (7,905/μL (interquartile range (IQR) 2,419 to 37,400) and 85% (IQR 70.3 to 93.8) versus 450 (IQR 167 to 1,215) and 46% (IQR 28.5 to 67.4%), P < .001). The respective areas under the curves were 0.916 (95% confidence interval 0.862 to 0.970) for leukocyte count and 0.821 (95% confidence interval 0.739 to 0.902) for % PMN. We calculated an optimal cut-off value of 1,200 leukocytes/μL (Sensitivity 94.5%/specificity 75.5%) and 63% PMN (Sensitivity 85.5%/specificity 73.6%) to define PJI. Established thresholds were less sensitive, but more specific. The "infection likely" scenario of the European Bone and Joint Infection Society (EBJIS) definition was closest to the calculated thresholds.

CONCLUSION

Currently used thresholds for leukocyte cell count and %PMN to define PJI were less sensitive and specific in the diagnosis of PJI in metal-on-metal RHK knees. Surgeons must consider lower cut-off values when evaluating such implants for PJI.

Для цитирования: Theil Christoph, Moellenbeck Burkhard, Schwarze Jan, Puetzler Jan, Klingebiel Sebastian, Bockholt Sebastian, Gosheger Georg. Can the Current Thresholds for Synovial Cell Count and Neutrophil Percentage to Diagnose Prosthetic Joint Infection be Applied to Metal-on-Metal Rotating Hinge Total Knee Arthroplasty?. The Journal of arthroplasty. 2023. DOI: 10.1016/j.arth.2023.08.073.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.