DOI 10.1097/brs.0b013e3181791af3
Reliability of readings of magnetic resonance imaging features of lumbar spinal stenosis.
Аннотация
STUDY
DESIGN
A reliability assessment of standardized magnetic resonance imaging (MRI) interpretations and measurements.
OBJECTIVE
To determine the intra- and inter-reader reliability of MRI features of lumbar spinal stenosis (SPS), including severity of central, subarticular, and foraminal stenoses, grading of nerve root impingement, and measurements of cross-sectional area of the spinal canal and thecal sac.
SUMMARY OF BACKGROUND DATA: MRI is commonly used to assess patients with spinal stenosis. Although a number of studies have evaluated the reliability of certain MRI characteristics, comprehensive evaluation of the reliability of MRI readings in spinal stenosis is lacking.
METHODS
Fifty-eight randomly selected MR images from patients with SPS enrolled in the Spine Patient Outcomes Research Trial were evaluated. Qualitative ratings of imaging features were performed according to defined criteria by 4 independent readers (3 radiologists and 1 orthopedic surgeon). A sample of 20 MRIs was reevaluated by each reader at least 1 month later. Weighted kappa statistics were used to characterize intra- and inter-reader reliability for qualitative rating data. Separate quantitative measurements were performed by 2 other radiologists. Intraclass correlation coefficients and summaries of measurement error were used to characterize reliability for quantitative measurements.
RESULTS
Intra-reader reliability was higher than inter-reader reliability for all features. Inter-reader reliability in assessing central stenosis was substantial, with an overall kappa of 0.73 (95% CI 0.69-0.77). Foraminal stenosis and nerve root impingement showed moderate to substantial agreement with overall kappa of 0.58 (95% CI 0.53-0.63) and 0.51 (95% CI 0.42-0.59), respectively. Subarticular zone stenosis yielded the poorest agreement (overall kappa 0.49; 95% CI 0.42-0.55) and showed marked variability in agreement between reader pairs. Quantitative measures showed inter-reader intraclass correlation coefficients ranging from 0.58 to 0.90. The mean absolute difference between readers in measured thecal sac area was 128 mm (13%).
CONCLUSION
The imaging characteristics of spinal stenosis assessed in this study showed moderate to substantial reliability; future studies should assess whether these findings have prognostic significance in SPS patients.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.