MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5606/ehc.2020.73416

Медицинская библиотека · Joint diseases and related surgery · 2020

Comparison of dynamic hip screw and antirotation screw with cannulated screw in the treatment of transcervical collum femoris fractures.

Şahin Adem, Agar Anıl, Gülabi Deniz, Ertürk Cemil

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study aims to compare the results of internal fixation with dynamic hip screw (DHS)/antirotation screw and conventional cannulated screw (CS) for femoral neck fracture.

PATIENTS AND

METHODS

This retrospective study included a total of 78 patients (57 males, 21 females) with collum femoris fractures treated with internal fixation between January 2015 and January 2019. Group 1 comprised 41 patients with a mean age of 45.7 years (range, 19 to 62 years) treated with DHSs/antirotation screws, while group 2 comprised 37 patients with a mean age of 41.9 years (range, 17 to 75 years) treated with CSs. The patients were evaluated for union, avascular necrosis (AVN), femoral neck shortness, operation time, duration of fluoroscopy exposure, and functional outcomes.

RESULTS

Age, gender, and Garden classification stages were similar in both groups. No significant difference was found between the groups in respect of AVN and non-union rates. The non-union rate was 12.2% in group 1 and 21.6% in group 2 (p>0.05). The duration of fluoroscopy exposure was statistically significantly higher in group 2 (p=0.001) and the operation time was statistically significantly longer in group 1 (p=0.001). In group 2, femoral neck shortness stature was significantly higher (p=0.007). At the final follow-up examination, the Harris hip score was statistically significantly higher in group 1 (p=0.04).

CONCLUSION

Dynamic hip screw/antirotation screw was a more relevant treatment method for transcervical femoral neck fractures compared to CS with more favorable functional outcomes and less fluoroscopy exposure.

Для цитирования: Şahin Adem, Agar Anıl, Gülabi Deniz, Ertürk Cemil. Comparison of dynamic hip screw and antirotation screw with cannulated screw in the treatment of transcervical collum femoris fractures.. Joint diseases and related surgery. 2020. DOI: 10.5606/ehc.2020.73416.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.