BACKGROUND
The use of double gloving has become a standard practice for joint replacement surgeons. However, since there are limited data on how gloves are contaminated during both primary and revision arthroplasty, no precise protocol exists to direct surgeons on when, or if, to change their gloves. The goals of this preliminary study were to evaluate the contamination of gloves during total joint arthroplasties (TJAs).
METHODS
We included 25 infected cases and 10 primaries, which were performed at the same institution using the same surgical protocol from 3 fellowship trained surgeons. Samples were taken every 20 minutes from the start of the surgery until the joint was irrigated. Procedural steps were noted. To evaluate cross-contamination during infected cases, we sampled gloves using blood agar plates. In primary cases, culture swabs of anterior chamfer cuts and sterile instruments on the back table were used as negative controls. Next-generation sequencing (NGS) was used as an adjunct to identify low virulence bacteria.
RESULTS
In the primary cases, all samples were found culture negative but 3 (8.1%) of the 37 samples were found to have a low, unidentifiable bacterial mass via NGS testing. In the infected cases, 41 (59.4%) of the 69 samples yielded positive microbial results. The positivity rate was higher in the samples collected after the arthrotomy was performed (70%) compared to samples collected before the arthrotomy was performed (40%), and the surgeon was only dissecting superficial layers (P = .502).
CONCLUSION
Gloves seem to be a common source of cross-contamination in the intraoperative field during revision TJA. Due to the higher percent of positive samples following the opening of the joint, we hypothesize that the arthrotomy allows for the spread of bacteria across the operative site. While further investigation is necessary to formulate a precise protocol for the changing of gloves during TJA, it may be beneficial to perform a thorough irrigation of the joint and change of the gloves immediately following arthrotomy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.