Effects of rotary ultrasonic bone drilling on cutting force and temperature in the human bones.

Singh Ravinder Pal, Pandey Pulak Mohan, Behera Chittaranjan, Mridha Asit Ranjan

СтатьяПеревод в очереди

Аннотация

Efficacy and outcomes of osteosynthesis depend on various factors including types of injury and repair, host factors, characteristics of implant materials and type of implantation. One of the most important host factors appears to be the extent of bone damage due to the mechanical force and thermal injury which are produced at cutting site during bone drilling. The temperature above the critical temperature (47 °C) produces thermal osteonecrosis in the bones. In the present work, experimental investigations were performed to determine the effect of drilling parameters (rotational speed, feed rate and drill diameter) and techniques (conventional surgical bone drilling and rotary ultrasonic bone drilling) on cutting force and temperature generated during bone drilling. The drilling experiments were performed by a newly developed bone drilling machine on different types of human bones (femur, tibia and fibula) having different biological structure and mechanical behaviour. The bone samples were procured from male cadavers with the age of second to fourth decades. The results revealed that there was a significant difference (p < 0.05) in cutting force and temperature rise for rotary ultrasonic bone drilling and conventional surgical bone drilling. The cutting force obtained in rotary ultrasonic bone drilling was 30%-40%, whereas temperature generated was 50%-55% lesser than conventional surgical bone drilling process for drilling in all types of bones. It was also found that the cutting force increased with increasing feed rate, drill diameter and decrease in rotational speed, whereas increasing rotational speed, drill diameter and feed rate resulted in higher heat generation during bone drilling. Both the techniques revealed that the axial cutting force and the temperature rise were significantly higher in femur and tibia compared with the fibula for all combinations of process parameters.

Для цитирования: Singh Ravinder Pal, Pandey Pulak Mohan, Behera Chittaranjan, Mridha Asit Ranjan. Effects of rotary ultrasonic bone drilling on cutting force and temperature in the human bones.. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. 2020. DOI: 10.1177/0954411920925254.

Предметные рубрики MeSH