MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1213/ane.0b013e31822c94a8

Медицинская библиотека · Anesthesia and analgesia · 2011

Lack of effectiveness of the pulmonary artery catheter in cardiac surgery.

Schwann Nanette M, Hillel Zak, Hoeft Andreas, Barash Paul, Möhnle Patrick, Miao Yinghui, Mangano Dennis T

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The pulmonary artery catheter (PAC) continues to be used for monitoring of hemodynamics in patients undergoing coronary artery bypass graft (CABG) surgery despite concerns raised in other settings regarding both effectiveness and safety. Given the relative paucity of data regarding its use in CABG patients, and given entrenched practice patterns, we assessed the impact of PAC use on fatal and nonfatal CABG outcomes as practiced at a diverse set of medical centers.

METHODS

Using a formal prospective observational study design, 5065 CABG patients from 70 centers were enrolled between November 1996 and June 2000 using a systemic sampling protocol. Propensity score matched-pair analysis was used to adjust for differences in likelihood of PAC insertion. The predefined composite endpoint was the occurrence of any of the following: death (any cause), cardiac dysfunction (myocardial infarction or congestive heart failure), cerebral dysfunction (stroke or encephalopathy), renal dysfunction (dysfunction or failure), or pulmonary dysfunction (acute respiratory distress syndrome). Secondary variables included treatment indices (inotrope use, fluid administration), duration of postoperative intubation, and intensive care unit length of stay. After categorization based on PAC and transesophageal echocardiography use (both, neither, PAC only, transesophageal echocardiography only), we performed the primary analysis contrasting PAC only and neither (total, 3321 patients), from which propensity paring yielded 1273 matched pairs.

RESULTS

The primary endpoint occurred in 271 PAC patients versus 196 without PAC (21.3% vs.15.4%; adjusted odds ratio [AOR], 1.68; 95% confidence interval [CI], 1.24 to 2.26; P<0.001). The PAC group had an increased risk of all-cause mortality, 3.5% vs 1.7% (AOR, 2.08; 95% CI, 1.11 to 3.88; P=0.02) and an increased risk of cardiac (AOR, 1.58; 95% CI, 1.14 to 2.20; P=0.007), cerebral (AOR, 2.02; 95% CI, 1.08 to 3.77; P=0.03) and renal (AOR, 2.47; 95% CI, 1.68 to 3.62; P<0.001) morbid outcomes. PAC patients received inotropic drugs more frequently (57.8% vs 50.0%; P<0.001), had a larger positive IV fluid balance after surgery (3220 mL vs 3022 mL; P=0.003), and experienced longer time to tracheal extubation (15.40 hours [11.28/20.80] versus 13.18 hours [9.58/19.33], median plus Q1/Q3 interquartile range; P<0.0001). Use of PAC was also associated with prolonged intensive care unit stay (14.5% vs 10.1%; AOR, 1.55; 95% CI, 1.06 to 2.27; P=0.02).

CONCLUSIONS

Use of a PAC during CABG surgery was associated with increased mortality and a higher risk of severe end-organ complications in this propensity-matched observational study. A randomized controlled trial with defined hemodynamic goals would be ideal to either confirm or refute our findings.

Для цитирования: Schwann Nanette M, Hillel Zak, Hoeft Andreas, Barash Paul, Möhnle Patrick, Miao Yinghui, Mangano Dennis T. Lack of effectiveness of the pulmonary artery catheter in cardiac surgery.. Anesthesia and analgesia. 2011. DOI: 10.1213/ane.0b013e31822c94a8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.