MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiomech.2022.105735

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2022

Biomechanical analysis of atlantoaxial intraarticular fusion cages with posterior pedicle screws fixation using finite element method.

Gu Yongjie, He Shisheng, Wang Yang, Xu Dingli, Ma Weihu, Zhao Liujun

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cadaveric biomechanical studies indicated that atlantoaxial intraarticular fusion cages with posterior pedicle screws fixation could increase the multi-axial rigidity. However, the stress distribution of the fixation construct is still unclear.

METHODS

From computed tomography images, a nonlinear intact three-dimensional C0-2 finite element model was developed and validated. Four finite element models were reconstructed: intact model, unstable model, bilateral atlantoaxial pedicle screws combined bilateral cages model, bilateral atlantoaxial pedicle screws model. The range of motion and maximum von Mises stresses were compared under flexion, extension, lateral bending, and axial rotation.

FINDINGS: Compared with unstable model, both bilateral atlantoaxial pedicle screws combined bilateral cages model and bilateral atlantoaxial pedicle screws model fixation techniques reduced range of motion by >99% in extension, flexion, lateral bending and axial rotation. For bilateral atlantoaxial pedicle screws combined bilateral cages model, the maximum von Mises stress was in the base of the C2 screw head site. In the bilateral atlantoaxial pedicle screws model was stressed at the rod linked C1 and C2 screws. Compared with bilateral atlantoaxial pedicle screws model, bilateral atlantoaxial pedicle screws combined bilateral cages model reduced the maximum von Mises stress on the implants by >90% in extension, flexion, lateral bending and axial rotation.

INTERPRETATION: The finite element model study indicated that, compared with posterior C1-C2 pedicle screws fixation, atlantoaxial intraarticular fusion cages with posterior pedicle screws fixation could not only significantly restore stability to the atlantoaxial junction, but also dramatically reduce the maximum von Mises stress in the C1-C2 pedicle screws.

Для цитирования: Gu Yongjie, He Shisheng, Wang Yang, Xu Dingli, Ma Weihu, Zhao Liujun. Biomechanical analysis of atlantoaxial intraarticular fusion cages with posterior pedicle screws fixation using finite element method.. Clinical biomechanics (Bristol, Avon). 2022. DOI: 10.1016/j.clinbiomech.2022.105735.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.