MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.joca.2008.06.009

Медицинская библиотека · Osteoarthritis and cartilage · 2008

Comparative evaluation of three semi-quantitative radiographic grading techniques for hip osteoarthritis in terms of validity and reproducibility in 1404 radiographs: report of the OARSI-OMERACT Task Force.

Gossec L, Jordan J M, Lam M-A, Fang F, Renner J B, Davis A, Hawker G A, Dougados M, Maillefert J F, OARSI-OMERACT task force "total articular replacement as outcome measure in OA"

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The objective of this work was to compare the measurement properties of three categorical X-ray scoring methods for hip osteoarthritis (OA).

METHODS

In data obtained from trials and cohorts, radiographs were evaluated using the Kellgren and Lawrence (KL) grading system, the Osteoarthritis Research Society International (OARSI) joint space narrowing score, and quantitative measurement of joint space width (JSW), analysed as a categorical variable according to Croft and Lane's cutoffs (1.5, 2.5 and 3mm). Predictive validity was assessed through logistic regression to predict joint replacement in one database. Construct validity was assessed through logistic regression between pain and function and X-ray stages. Inter-observer and intra-observer reliability were assessed in 50 subjects by weighted kappa. Sensitivity to change was assessed in 50 patients over a 24-month interval, by standardized response mean (SRM).

RESULTS

Radiographs were available from one trial and two cohorts (1404 X-rays). All three methods predicted joint replacement in the trial. Correlation with clinical parameters was low for the three scoring methods, except for the single community-based cohort. Interrater reliability was higher for categorical JSW (kappa, 0.71 vs 0.44 and 0.47 for KL and OARSI, respectively). Intrarater reliability was similar for the three methods (0.79 vs 0.69 and 0.81). Sensitivity to change was higher for categorical JSW than KL and OARSI (SRM, 0.77 vs 0.28 and 0.35).

CONCLUSION

Categorical JSW has similar validity and higher sensitivity to change than the other categorical scoring techniques in hip OA. These results indicate categorical JSW may be the preferred method to evaluate structural severity in hip OA clinical trials.

Для цитирования: Gossec L, Jordan J M, Lam M-A, Fang F, Renner J B, Davis A, Hawker G A, Dougados M, Maillefert J F, OARSI-OMERACT task force "total articular replacement as outcome measure in OA". Comparative evaluation of three semi-quantitative radiographic grading techniques for hip osteoarthritis in terms of validity and reproducibility in 1404 radiographs: report of the OARSI-OMERACT Task Force.. Osteoarthritis and cartilage. 2008. DOI: 10.1016/j.joca.2008.06.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.