MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/hae.12296

Медицинская библиотека · Haemophilia : the official journal of the World Federation of Hemophilia · 2013

Comparative field study evaluating the activity of recombinant factor VIII Fc fusion protein in plasma samples at clinical haemostasis laboratories.

Sommer J M, Moore N, McGuffie-Valentine B, Bardan S, Buyue Y, Kamphaus G D, Konkle B A, Pierce G F

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Discrepancies exist for some of the modified coagulation factors when assayed with different one-stage clotting and chromogenic substrate assay reagents. The aim of this study was to evaluate the performance of a recombinant factor VIII Fc fusion protein (rFVIIIFc), currently in clinical development for the treatment of severe haemophilia A, in a variety of one-stage clotting and chromogenic substrate assays in clinical haemostasis laboratories. Haemophilic plasma samples spiked with rFVIIIFc or Advate(®) at 0.05, 0.20 or 0.80 IU mL(-1) were tested by 30 laboratories using their routine procedures and plasma standards. Data were evaluated for intra- and inter-laboratory variation, accuracy and possible rFVIIIFc-specific assay discrepancies. For the one-stage assay, mean recovery was 95% to 100% of expected for both Advate(®) and rFVIIIFc at 0.8 IU mL(-1). Intra-laboratory percent coefficient of variance (CV) ranged from 6.3% to 7.8% for Advate(®), and 6.0% to 10.3% for rFVIIIFc. Inter-laboratory CV ranged from 10% for Advate(®) and 16% for rFVIIIFc at 0.8 IU mL(-1), to over 30% at 0.05 IU mL(-1) for both products. For the chromogenic substrate assay, the average FVIII recovery was 107% ± 5% and 124% ± 8% of label potency across the three concentrations of Advate(®) and rFVIIIFc, respectively. Plasma rFVIIIFc levels can be monitored by either the one-stage or the chromogenic substrate assay routinely performed in clinical laboratories without the need for a product-specific rFVIIIFc laboratory standard. Accuracy by the one-stage assay was comparable to that of Advate(®), while marginally higher results may be observed for rFVIIIFc when using the chromogenic assay.

Для цитирования: Sommer J M, Moore N, McGuffie-Valentine B, Bardan S, Buyue Y, Kamphaus G D, Konkle B A, Pierce G F. Comparative field study evaluating the activity of recombinant factor VIII Fc fusion protein in plasma samples at clinical haemostasis laboratories.. Haemophilia : the official journal of the World Federation of Hemophilia. 2013. DOI: 10.1111/hae.12296.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.