INTRODUCTION/AIMS: VCP multisystem proteinopathy 1 (MSP1), encompassing inclusion body myopathy (IBM), Paget's disease of bone (PDB) and frontotemporal dementia (FTD) (IBMPFD), features progressive muscle weakness, fatty infiltration, and disorganized bone structure in Pagetic bones. The aim of this study is to utilize dual-energy x-ray absorptiometry (DXA) parameters to examine it as a biomarker of muscle and bone disease in MSP1.

METHODS

DXA scans were obtained in 28 patients to assess body composition parameters (bone mineral density [BMD], T-score, total fat, and lean mass) across different groups: total VCP disease (n = 19), including myopathy without Paget's ("myopathy"; n = 12) and myopathy with Paget's ("Paget"; n = 7), and unaffected first-degree relatives serving as controls (n = 6).

RESULTS

In the VCP disease group, significant declines in left hip BMD and Z-scores were noted versus the control group (p ≤ .03). The VCP disease group showed decreased whole body lean mass % (p = .04), and increased total body fat % (p = .04) compared to controls. Subgroup comparisons indicated osteopenia in 33.3% and osteoporosis in 8.3% of the myopathy group, with 14.3% exhibiting osteopenia in the Paget group. Moreover, the Paget group displayed higher lumbar L1-L4 T-score values than the myopathy group.

DISCUSSION: In MSP1, DXA revealed reduced bone and lean mass, and increased fat mass. These DXA insights could aid in monitoring disease progression of muscle loss and secondary osteopenia/osteoporosis in MSP1, providing value both clinically and in clinical research.

Для цитирования: Columbres Rod Carlo Agram, Luu Vu, Nguyen Minh, Kimonis Virginia. Cross-sectional study of patients with VCP multisystem proteinopathy 1 using dual-energy x-ray absorptiometry.. Muscle & nerve. 2024. DOI: 10.1002/mus.28095.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.