Spontaneous fracture of a titanium mesh cranioplasty implant in a child: A case report.

Zhang Rui, Gao Zhe, Zhu Yong-Jie, Wang Xin-Fa, Wang Gang, He Jun-Ping

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Titanium mesh cranioplasty is often performed after decompressive craniectomy. Spontaneous fracture of the titanium prosthesis is an extremely rare postoperative complication. Here, we report a 10-year-old boy who presented with a spontaneous fracture of titanium mesh without antecedent head trauma.

CASE SUMMARY: A 10-year-old boy presented with a 1-wk history of a tender bulge over the left temporo-parieto-occipital scalp. He had undergone a temporo-parieto-occipital titanium mesh cranioplasty 26 mo previously. He denied antecedent head trauma. Computerized tomography disclosed a perpendicular fissure in the titanium mesh, suggesting a diagnosis of spontaneous titanium mesh fracture. He underwent a second temporo-parieto-occipital cranioplasty and made an uneventful recovery. Three-dimensional modeling and finite element analyses were used to explore potential risk factors of titanium mesh fracture.

CONCLUSION

We report a case of spontaneous fracture of a titanium mesh cranioplasty implant. The current case and literature review indicate that titanium mesh implants should be well-anchored to the base of bony defects to prevent fatigue-induced fractures.

Для цитирования: Zhang Rui, Gao Zhe, Zhu Yong-Jie, Wang Xin-Fa, Wang Gang, He Jun-Ping. Spontaneous fracture of a titanium mesh cranioplasty implant in a child: A case report.. World journal of clinical cases. 2023. DOI: 10.12998/wjcc.v11.i7.1593.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.