MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2340/17453674.2025.44034

Медицинская библиотека · Acta orthopaedica · 2025

A comparison of cancellous screws in a sliding compression configuration and angle-stable sliding compression implants for internal fixation of femoral neck fractures in the non-elderly predominantly below 65 years: a systematic review and meta-analysis.

Hansen Michaela M, Nielsen Mads S, Gundtoft Per H, Stilling Maiken, Ding Ming, Viberg Bjarke

СтатьяСистематический обзорМетаанализСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Internal fixation is the preferred treatment in the non-elderly with femoral neck fractures, regardless of fracture displacement. High complication rates are reported, in particular for displaced fractures. We aimed to compare cancellous screws with angle-stable sliding compression implants for internal fixation of femoral neck fractures in the non-elderly.

METHODS

A systematic search was carried out in Medline, Embase, Scopus, and Cochrane. The search results were screened by 2 reviewers using Covidence and assessed for risk of bias. All comparative studies were included. The studies reported at least 1 of the following outcomes: avascular necrosis, fixation failure/cut-out, non-union, any complication, reoperation, femoral neck shortening, or Harris Hip Score (HHS). Dichotomous outcomes are reported as risk ratio (RR) and continuous outcomes as mean difference (MD). All effect measures use a random effects model.

RESULTS

The search yielded 23 studies eligible for inclusion: 4 randomized controlled trials (RCTs) and 19 retrospective cohort trials, including 1,844 fractures. Only 1 study had low risk of bias. The results demonstrated no difference in RCTs alone. Analysis of all studies showed superior outcomes in favor of angle-stable sliding compression implants for fixation failure/cut-out (RR 0.54, 95% confidence interval [CI] 0.31-0.94), any complication (RR 0.49, CI 0.28-0.87), shortening > 5 mm (RR 0.54, CI 0.37-0.80), and HHS 6-24 months (MD 3.1, CI 1.8-4.4).

CONCLUSION

RCTs alone showed no significant differences between implant types. When including retrospective studies, angle-stable sliding compression implants demonstrated some advantages. The strength of evidence is limited by the predominance of retrospective cohort studies and high risk of bias in the included studies.

Для цитирования: Hansen Michaela M, Nielsen Mads S, Gundtoft Per H, Stilling Maiken, Ding Ming, Viberg Bjarke. A comparison of cancellous screws in a sliding compression configuration and angle-stable sliding compression implants for internal fixation of femoral neck fractures in the non-elderly predominantly below 65 years: a systematic review and meta-analysis.. Acta orthopaedica. 2025. DOI: 10.2340/17453674.2025.44034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.