MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1590/1806-9282.20210729

Медицинская библиотека · Revista da Associacao Medica Brasileira (1992) · 2022

Cadaveric study of anatomical measurement of isthmus parameters of lumbar spine to guide cortical bone screw placement.

Rexiti Paerhati, Aikeremu Dilimulati, Wang Shuiquan, Abuduwali Nueraihemaiti, Kahaer Alafate, Sheng Weibin

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To reduce surgical exposure and improve accuracy, this study evaluated the anatomical distance parameter D (including D1, D2, and D3) of the lumbar isthmus for cortical bone screw insertion.

METHODS

A total of 25 structurally complete lumbar dry specimens were used for lumbar anatomy measurements. The six cadaver specimens were divided into upper and lower parts on the plane of the T11-T12 vertebrae, and we use the lower parts. Therefore, six lumbar wet specimens and another four complete lumbar dry specimens were selected. The lumbar isthmus tangent point was considered a coordinate origin, and the insertion point was determined through translating the distance of D1 value to the midline of the vertebral body horizontally and then vertically moved toward inferior board of the transverse process with the distance of D3 value.

RESULTS

In four dry and six wet intact lumbar specimens, cortical bone screws were placed according to the average value of the isthmus parameter D. A total of 100 trajectories were verified in specimens by X-ray and computed topography scan to evaluate the safety, accuracy, and feasibility of the surgical use of isthmus parameter D. Using this parameter, the rates of excellent screw placement were 95% (38/40) in four dry specimens and 88.7% (53/60) in six wet specimens.

CONCLUSION

The isthmus parameter D is easier to use by the operator, which can improve surgical accuracy and reduce operation time.

LEVEL OF EVIDENCE: Level IV, prospective study.

Для цитирования: Rexiti Paerhati, Aikeremu Dilimulati, Wang Shuiquan, Abuduwali Nueraihemaiti, Kahaer Alafate, Sheng Weibin. Cadaveric study of anatomical measurement of isthmus parameters of lumbar spine to guide cortical bone screw placement.. Revista da Associacao Medica Brasileira (1992). 2022. DOI: 10.1590/1806-9282.20210729.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.