MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1302/0301-620x.104b9.bjj-2021-1672.r1

Медицинская библиотека · The bone & joint journal · 2022

Synovial fluid alpha-defensin in periprosthetic knee infection workup : liquid chromatography-mass spectrometry detection of alpha-defensin in synovial fluid.

Balato Giovanni, Dall'Anese Riccardo, Balboni Fiamma, Ascione Tiziana, Pezzati Paola, Bartolini Giuseppe, Quercioli Massimo, Baldini Andrea

СтатьяПеревод в очереди

Аннотация

AIMS: The diagnosis of periprosthetic joint infection (PJI) continues to present a significant clinical challenge. New biomarkers have been proposed to support clinical decision-making; among them, synovial fluid alpha-defensin has gained interest. Current research methodology suggests reference methods are needed to establish solid evidence for use of the test. This prospective study aims to evaluate the diagnostic accuracy of high-performance liquid chromatography coupled with the mass spectrometry (LC-MS) method to detect alpha-defensin in synovial fluid.

METHODS

Between October 2017 and September 2019, we collected synovial fluid samples from patients scheduled to undergo revision surgery for painful total knee arthroplasty (TKA). The International Consensus Meeting criteria were used to classify 33 PJIs and 92 aseptic joints. LC-MS assay was performed to measure alpha-defensin in synovial fluid of all included patients. Sensitivity, specificity, positive predictive value, negative predictive value, and the area under the receiver operating characteristic curve (AUC) were calculated to define the test diagnostic accuracy.

RESULTS

The AUC was 0.99 (95% confidence interval (CI) 0.98 to 1.00). Receiver operating characteristic (ROC) analysis showed that the optimal cut-off value of synovial fluid alpha-defensin was 1.0 μg/l. The sensitivity of alpha-defensin was 100% (95% CI 96 to 100), the specificity was 97% (95% CI 90 to 98), the positive predictive value was 89.2% (95% CI 82 to 94), and negative predictive value was 100% (95% CI 96 to 100). ROC analysis demonstrated an AUC of 0.99 (95% CI 0.98 to 1.0).

CONCLUSION

The present study confirms the utility of alpha-defensin in the synovial fluid in patients with painful TKA to select cases of PJI. Since LC-MS is still a time-consuming technology and is available in highly specialized laboratories, further translational research studies are needed to take this evidence into routine procedures and promote a new diagnostic approach.Cite this article: Bone Joint J 2022;104-B(9):1047-1051.

Для цитирования: Balato Giovanni, Dall'Anese Riccardo, Balboni Fiamma, Ascione Tiziana, Pezzati Paola, Bartolini Giuseppe, Quercioli Massimo, Baldini Andrea. Synovial fluid alpha-defensin in periprosthetic knee infection workup : liquid chromatography-mass spectrometry detection of alpha-defensin in synovial fluid.. The bone & joint journal. 2022. DOI: 10.1302/0301-620x.104b9.bjj-2021-1672.r1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.