BACKGROUND

To investigate the stiffness and strength of completely unstable pelvic fractures fixated both anteriorly and posteriorly under cyclic loading conditions, the authors conducted a randomized, comparative, cadaveric study.

METHODS

In 12 specimens, a Tile C1 pelvic fracture was created. The authors compared the intact situation to anterior plate fixation combined with one or two sacroiliac screws. In 2,000 measurements, each pelvis was loaded with a maximum of 400 N. The translation and rotation stiffness of the fixations were measured using a three-dimensional video system. Furthermore, the load to failure and the number of cycles before failure were determined.

RESULTS

Both translation and rotation stiffness of the intact pelvis were superior to the fixated pelvis. No difference in stiffness was found between the techniques with one or two sacroiliac screws. However, a significantly higher load to failure and significantly more loading cycles before failure could be achieved using two sacroiliac screws compared with one screw.

CONCLUSION

Although the combination of anterior plate fixation combined with two sacroiliac screws is not as stable as the intact pelvis, in this study, embalmed aged pelves could be loaded repeatedly with physiologic forces. Given the fact that the average trauma patient is younger and given the fact that the quality (or grip) of the fixation was a significant covariable for longer endurance of the fixation, this suggests that direct postoperative weight bearing could be possible if these results are confirmed in further research.

Для цитирования: van Zwienen C M A, van den Bosch Eric W, Hoek van Dijke G A, Snijders C J, van Vugt Arie B. Cyclic loading of sacroiliac screws in Tile C pelvic fractures.. The Journal of trauma. 2005. DOI: 10.1097/01.ta.0000158515.58494.11.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.