MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00776-012-0231-y

Медицинская библиотека · Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association · 2012

Evaluation of magnetic resonance imaging and clinical outcome after tissue-engineered cartilage implantation: prospective 6-year follow-up study.

Takazawa Kobun, Adachi Nobuo, Deie Masataka, Kamei Goki, Uchio Yuji, Iwasa Junji, Kumahashi Nobuyuki, Tadenuma Taku, Kuwata Suguru, Yasuda Kazunori, Tohyama Harukazu, Minami Akio, Muneta Takeshi, Takahashi Shigeo, Ochi Mitsuo

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Autologous chondrocyte implantation (ACI) is an important procedure when repairing cartilage defects of the knee. We previously reported several basic studies on tissue-engineered cartilage, and conducted a multicenter clinical study in 2009. In this clinical study, we evaluated the patients' clinical scores and MRI findings before and after tissue-engineered cartilage implantation, and compared the data obtained at 1 year and approximately 6 years post-implantation.

METHODS

Fourteen patients who underwent implantation of tissue-engineered cartilage to repair cartilage defects of the knee were evaluated. Tissue-engineered cartilage was produced by culturing autologous chondrocytes three dimensionally in atelocollagen gel. The patients were evaluated clinically using the Lysholm score, and the original knee-function score at pre-implantation and at 1 year and approximately 6 years post-implantation. MRI scans were obtained at the same observation periods. A modified magnetic resonance observation of cartilage repair tissue (MOCART) system was used to quantify clinical efficacy based on the MRI findings.

RESULTS

In approximately 6 years of follow-up, none of the 14 patients reported any subjective symptoms of concern. The mean Lysholm score and the original knee-function score (63.0 ± 10.1, 59.9 ± 5.7) significantly improved at 1 year after implantation (86.4 ± 11.8, 94.1 ± 9.2), and were maintained until 6 years after implantation (89.8 ± 6.2, 89.9 ± 11.2), although some patients showed deterioration of Lysholm and original knee scores between 1 year post-implantation and the final follow-up. The mean MOCART score was 13.2 ± 12.0 pre-implantation, and 62.5 ± 24.7 at 1 year and 70.7 ± 22.7 at approximately 6 years post-implantation. The MOCART scores at 1 year and 6 years were significantly higher than the pre-implantation score, but there was no significant difference between the scores at 1 and 6 years, indicating that the MRI results at 1 year after implantation were maintained for the next 5 years.

CONCLUSIONS

The clinical scores and MRI findings after implantation of tissue-engineered cartilage were improved at 1 year after implantation and were maintained until 6 years after implantation.

Для цитирования: Takazawa Kobun, Adachi Nobuo, Deie Masataka, Kamei Goki, Uchio Yuji, Iwasa Junji, Kumahashi Nobuyuki, Tadenuma Taku, Kuwata Suguru, Yasuda Kazunori, Tohyama Harukazu, Minami Akio, Muneta Takeshi, Takahashi Shigeo, Ochi Mitsuo. Evaluation of magnetic resonance imaging and clinical outcome after tissue-engineered cartilage implantation: prospective 6-year follow-up study.. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. 2012. DOI: 10.1007/s00776-012-0231-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.