MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-022-07262-3

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022

Adjacent segments biomechanics following lumbar fusion surgery: a musculoskeletal finite element model study.

Ebrahimkhani Mahdi, Arjmand Navid, Shirazi-Adl Aboulfazl

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: This study exploits a novel musculoskeletal finite element (MS-FE) spine model to evaluate the post-fusion (L4-L5) alterations in adjacent segment kinetics.

METHODS

Unlike the existing MS models with idealized representation of spinal joints, this model predicts stress/strain distributions in all passive tissues while organically coupled to a MS model. This generic (in terms of musculature and material properties) model uses population-based in vivo vertebral sagittal rotations, gravity loads, and an optimization algorithm to calculate muscle forces. Simulations represent individuals with an intact L4-L5, a preoperative severely degenerated L4-L5 (by reducing the disc height by ~ 60% and removing the nucleus incompressibility), and a postoperative fused L4-L5 segment with either a fixed or an altered lumbopelvic rhythm with respect to the intact condition (based on clinical observations). Changes in spine kinematics and back muscle cross-sectional areas (due to intraoperative injuries) are considered based on in vivo data while simulating three activities in upright/flexed postures.

RESULTS

Postoperative changes in some adjacent segment kinetics were found considerable (i.e., larger than 25%) that depended on the postoperative lumbopelvic kinematics and preoperative L4-L5 disc condition. Postoperative alterations in adjacent disc shear, facet/ligament forces, and annulus stresses/strains were greater (> 25%) than those found in intradiscal pressure and compression (< 25%). Kinetics of the lower (L5-S1) and upper (L3-L4) adjacent segments were altered to different degrees.

CONCLUSION

Alterations in segmental rotations mainly affected adjacent disc shear forces, facet/ligament forces, and annulus/collagen fibers stresses/strains. An altered lumbopelvic rhythm (increased pelvis rotation) tends to mitigate some of these surgically induced changes.

Для цитирования: Ebrahimkhani Mahdi, Arjmand Navid, Shirazi-Adl Aboulfazl. Adjacent segments biomechanics following lumbar fusion surgery: a musculoskeletal finite element model study.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2022. DOI: 10.1007/s00586-022-07262-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.