Effects of rhBMP-2-loaded hydroxyapatite granules/beta-tricalcium phosphate hydrogel (HA/β-TCP/hydrogel) composite on a rat model of caudal intervertebral fusion.

Nakagawa Shinichi, Okada Rintaro, Kushioka Junichi, Kodama Joe, Tsukazaki Hiroyuki, Bal Zeynep, Tateiwa Daisuke, Ukon Yuichiro, Hirai Hiromasa, Makino Takahiro, Takenaka Shota, Okada Seiji, Kaito Takashi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The effects and inflammation-related side effects of bone morphogenetic protein (BMP)-2 on posterior lumbar interbody fusion are controversial. One of the potential causes for the inconsistent results is the uncontrolled release of BMP-2 from the collagen carrier. Therefore, BMP delivery systems that support effective bone regeneration while attenuating the side effects are strongly sought for. We developed NOVOSIS putty (NP), a novel composite material of hydroxyapatite (HA), beta-tricalcium phosphate (β-TCP)/hydrogel, and BMP-2, which can sustainably release BMP-2 over 2 weeks. This study was aimed at comparing the effects and side effects of NP and collagen sponge (CS) containing BMP-2 using a rat caudal intervertebral fusion model. The fusion rates of NP with low and high doses of BMP-2 were significantly higher than those of an iliac bone (IB) graft, but those of CS with low and high doses of BMP-2 were not different from those of the IB graft. Furthermore, the incidences of ectopic bone formation and soft tissue swelling were significantly lower in the NP group than in the CS group. The HA/β-TCP/hydrogel carrier enabled superior bone induction with low-dose BMP-2 and decreased the incidence of side effects caused by high-dose BMP-2 vis-à-vis the collagen carrier.

Для цитирования: Nakagawa Shinichi, Okada Rintaro, Kushioka Junichi, Kodama Joe, Tsukazaki Hiroyuki, Bal Zeynep, Tateiwa Daisuke, Ukon Yuichiro, Hirai Hiromasa, Makino Takahiro, Takenaka Shota, Okada Seiji, Kaito Takashi. Effects of rhBMP-2-loaded hydroxyapatite granules/beta-tricalcium phosphate hydrogel (HA/β-TCP/hydrogel) composite on a rat model of caudal intervertebral fusion.. Scientific reports. 2022. DOI: 10.1038/s41598-022-12082-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.