MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s40477-024-00886-9

Медицинская библиотека · Journal of ultrasound · 2024

Biceps brachii elastography in well-trained men post eccentric exercise-induced muscle damage.

Brandão Maria Clara Albuquerque, Matias Lino de Azevedo, da Matta Thiago Torres, de Oliveira Liliam Fernandes

СтатьяПеревод в очереди

Аннотация

PURPOSE: Recent advancements in elastography techniques, specifically supersonic shearwave elastography (SWE), have enabled non-invasive assessment of muscle stiffness. However, there is limited research on the immediate and short-term effects of eccentric exercise-induced muscle damage (EIMD) in well-trained individuals. This study aimed to follow up on the effects of eccentric training on the biceps brachialis stiffness by supersonic shearwave imaging (SSI) as well as the soreness and elbow flexion maximal voluntary isometric contraction (MVIC), immediately post-intervention, at 10 min, 48 h, and 96 h in well-trained men.

METHODS

Thirteen well-trained males participated in the study. Baseline measurements of elastography images, MVIC of the elbow flexors, and muscle soreness were obtained. The participants performed an eccentric exercise protocol (4 sets X 10 repetitions) on the dynamometer isokinetic and elastography measurements were repeated immediately post-exercise, at 10 min, 48 h, and 96 h.

RESULTS

Significant reductions in stiffness (measured by shear modulus (µ)) were observed immediately and at 10 min post-exercise. MVIC exhibited significant reductions immediately after, 10 min, and 48 h compared to baseline measurements. Muscle soreness peaked at 48 h, persisting until 96 h.

CONCLUSIONS

The BB stiffness and MVIC reduction immediately post-eccentric exercise in well-trained men, suggest the potential involvement of mechanical stress and sarcomere rupture. Trained individuals may exhibit a distinct response to EIMD compared to untrained individuals, highlighting the applicability of elastography in monitoring acute biomechanical changes following high-intensity exercise.

Для цитирования: Brandão Maria Clara Albuquerque, Matias Lino de Azevedo, da Matta Thiago Torres, de Oliveira Liliam Fernandes. Biceps brachii elastography in well-trained men post eccentric exercise-induced muscle damage.. Journal of ultrasound. 2024. DOI: 10.1007/s40477-024-00886-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.