MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.spinee.2021.10.001

Медицинская библиотека · The spine journal : official journal of the North American Spine Society · 2021

Quantitative Romberg using a force plate: an objective measure for cervical myelopathy.

Mkorombindo Tino, Glassman Steven D, Gum Jeffrey L, Brown Morgan E, Daniels Christy L, Carreon Leah Y

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND CONTEXT: Surgical decision making for cervical spondylotic myelopathy (CSM) relies on evaluation of symptoms and physical examination. The Romberg test is a clinical exam used to identify balance issues with CSM. However, the Romberg test has a subjective interpretation and has a binary (positive or negative) result.

PURPOSE: This study aims to compare force plate pressure readings during a standard Romberg test in patients with CSM to age-matched normal healthy volunteers.

STUDY DESIGN/

SETTING

Prospective cross sectional observational comparative cohort from a single multi-surgeon spine center.

PATIENT SAMPLE: Patients who were clinically diagnosed with CSM were compared to age-matched healthy volunteers without a clinical history of spine pathology.

OUTCOME MEASURES: Quantitative Romberg Force Plate Measurements

METHODS

Patients with CSM requiring surgery and healthy normal volunteers were asked to perform the Romberg test while on a force plate measuring the center of pressure (COP): standing up straight with arms extended for 30 seconds with eyes open, followed by 30 seconds with eyes closed. The change for total sway area, sway frequency and sway speed with eyes closed and eyes open were calculated and compared between patients with CSM and healthy volunteers.

RESULTS

Thirty-four CSM patients were age-matched to 34 healthy volunteers. There was a larger change in quantitative Romberg measurements with eyes open versus eyes closed in CSM patients compared to normal volunteers for maximum lateral movement (10.79 cm vs. 0.94 cm, p=.003), maximum anterior-posterior movement (15.06 cm vs. 10.00 cm p=.201), total lateral CoP movement (89.82cm vs. 18.71cm, p=.007), total AP CoP movement (154.68 cm vs. 87.47 cm, p=.601), total CoP trace movement (199.79 cm vs. 88.44 cm, p=.014), sway area (284.74 cm2 vs. 57.76 cm2, p=.006), and average speed (7.00 cm/s vs. 2.91 cm/s, p=.006).

DISCUSSION: Poor standing balance can be quantified in patients with CSM. Quantifying standing balance in patients with CSM shows significantly worse objective measures than age-matched healthy volunteers. The Romberg test on a force plate may help diagnose and evaluate patients with CSM, guide patient management and potentially grade the severity of spinal pathology. Further studies are needed to determine its utility in monitoring disease progression and measure treatment effectiveness.

Для цитирования: Mkorombindo Tino, Glassman Steven D, Gum Jeffrey L, Brown Morgan E, Daniels Christy L, Carreon Leah Y. Quantitative Romberg using a force plate: an objective measure for cervical myelopathy.. The spine journal : official journal of the North American Spine Society. 2021. DOI: 10.1016/j.spinee.2021.10.001.