MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/case24394

Медицинская библиотека · Journal of neurosurgery. Case lessons · 2024

Delayed percutaneous intradiscal hydrogel herniation causing neurological injury after minor trauma: illustrative case.

Gopalakrishnan S, Far R, Veilleux C, Swamy G, Yang MMH

Перевод в очереди

Аннотация

BACKGROUND

Percutaneous intradiscal hydrogel injection has been used to treat low-back pain (LBP) due to degenerative disc disease with or without mild radicular pain. Complications from these procedures are underreported. In this case lesson, the authors present a rare case of a patient with herniated intradiscal hydrogel following a minor trauma leading to neurological injury.

OBSERVATIONS: A 36-year-old female who had been previously treated with L4-5 and L5-S1 intradiscal hydrogel injections for LBP presented with painful, progressive right-sided lower-extremity weakness after experiencing a twisting trauma. Cross-sectional imaging results revealed a herniated hydrogel-based disc implant in the spinal canal. She underwent an urgent L4-5 laminectomy for decompression and removal of the herniated implant. A large annular defect was noted. Postoperatively, she had resolution of her right leg pain but experienced persistent right foot drop requiring an ankle-foot orthosis.

LESSONS: Herniated intradiscal hydrogel implants can lead to permanent neurological injury. While the risk factors for hydrogel herniation have not been elucidated, they can be related to pre-existing disruptions to the annulus and/or posterior longitudinal ligament, excess volume of hydrogel injection, and insufficient fixation time. Further research is needed to determine the safety and efficacy of this technology. https://thejns.org/doi/10.3171/CASE24394.

Для цитирования: Gopalakrishnan S, Far R, Veilleux C, Swamy G, Yang MMH. Delayed percutaneous intradiscal hydrogel herniation causing neurological injury after minor trauma: illustrative case.. Journal of neurosurgery. Case lessons. 2024. DOI: 10.3171/case24394.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.