MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4055/cios25137

Медицинская библиотека · Clinics in orthopedic surgery · 2025

Can the Inverted Application of the PHILOS Plate Be an Alternative in Extra-articular Distal Humerus Fractures? A Comparative Analysis with the Extra-articular Distal Humerus Plate.

Lee Yong-Jun, Lim Joon-Ryul, Yoon Tae-Hwan, Chun Yong-Min

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUD: The Proximal Humeral Internal Locking System (PHILOS) plate, designed for the treatment of proximal humeral fractures, demonstrates versatility when used in an inverted (upside-down) configuration. We aimed to retrospectively compare the clinical and radiographic outcomes of patients who underwent surgical treatment for extra-articular diaphyseal distal humeral fractures using either an extra-articular distal humerus plate (EADHP) or a modified PHILOS locking compression plate.

METHODS

This study included 58 patients: 39 in the EADHP group (group A) and 19 in the PHILOS plate group (group B). Clinical outcomes were assessed using a visual analog scale for pain rating, the Mayo Elbow Performance Score, and range of motion measurements. Radiological evaluation was performed using anteroposterior, lateral, and oblique views of the humerus. The presence of radial nerve symptoms was evaluated before and after surgery.

RESULTS

Patients in group B exhibited substantially shorter average operation times (105.8 minutes) and less mean blood loss (250.0 mL) than those in group A with an average operation time of 123.3 minutes and mean blood loss of 456.4 mL. Furthermore, a higher incidence of hardware removal was observed in group A (23.1%) than in group B (15.8%), with the procedure typically occurring approximately 15 months postoperatively in both groups. However, no significant discrepancies were found in clinical outcomes between the 2 groups, including time to fracture union and radial nerve injury rates, with no statistically significant distinctions detected between them.

CONCLUSIONS

Application of the modified PHILOS plate demonstrated outcomes comparable to those of the EADHP in treating extra-articular diaphyseal distal humerus fractures, with significantly reduced operation time and blood loss.

Для цитирования: Lee Yong-Jun, Lim Joon-Ryul, Yoon Tae-Hwan, Chun Yong-Min. Can the Inverted Application of the PHILOS Plate Be an Alternative in Extra-articular Distal Humerus Fractures? A Comparative Analysis with the Extra-articular Distal Humerus Plate.. Clinics in orthopedic surgery. 2025. DOI: 10.4055/cios25137.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.