Narrow diameter titanium dental implants fracture resistance after implantoplasty.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mickevičius Osvaldas, Pauliukevičius Artūras

Аннотация

BACKGROUND: There is a lack of evidence of possible implant fracture after implantoplasty due to decreased implant diameter.

PURPOSE: To compare narrow diameter titanium dental implants fracture resistance after implantoplasty performed by computer numerical control (CNC) lathe machine which helped to standardize study setting.

MATERIALS AND METHODS: Twelve (n=12) narrow diameter (3.6×11.0 mm) endosteal screw-shaped bone-level dental implants with an internal connection which are made from grade IV titanium were randomly divided into 2 groups containing six (n=6) implants each. The test group was exposed to implantoplasty using a computer numerical control (CNC) lathe-turning machine. Implantoplasty was performed removing 5.5 mm of implant threads from the implant coronal part downwards towards the apical part, which resulted in a 0.2 mm coronal diameter reduction. Implants from both groups were positioned on metal pipes using three-dimensional (3D) printed guides. The space inside the pipe was filled with epoxy resin. Every sample had an individually 3D-printed chrome-cobalt (Cr-Co) alloy crown, which distributed forces during the test. Implants were compressed in a universal testing machine. Statistical analysis was performed using IBM SPSS 29.0 software.

RESULTS: Performing implantoplasty with CNC lathe-turning machine was a success, which helped to standardize study settings. The control group showed average resistance to a maximum compressive force of 443.76 N, while the test group showed average resistance to a maximum compressive force of 409.42 N. No statistical significance was found between groups on the compressive force aspect.

CONCLUSION: This in vitro study shows that implantoplasty does not have a significant effect on decreasing fracture resistance of narrow diameter titanium dental implants.