MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2022.03.044

Медицинская библиотека · The Journal of arthroplasty · 2022

Inter-Rater Reliability of Clinical Testing for Laxity After Knee Arthroplasty.

Mears Simon C, Severin A Cecilia, Wang Junsig, Thostenson Jeff D, Mannen Erin M, Stambough Jeffrey B, Edwards Paul K, Barnes C Lowry

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

The clinical examination for laxity has been considered a mainstay in evaluation of the painful knee arthroplasty, especially for the diagnosis of instability. More than 10 mm of anterior-posterior (AP) translation in flexion has been described as important in the diagnosis of flexion instability. The inter-observer reliability of varus/valgus and AP laxity testing has not been tested.

METHODS

Ten subjects with prior to total knee arthroplasty (TKA) were examined by 4 fellowship-trained orthopedic knee arthroplasty surgeons. Each surgeon evaluated each subject in random order and was blinded to the results of the other surgeons. Each surgeon performed an anterior drawer test at 30 and 90 degrees of flexion and graded the instability as 0-5 mm, 5-10 mm or >10 mm. Varus-valgus testing was also graded. Motion capture was used during the examination to determine the joint position and estimate joint reaction force during the examination.

RESULTS

Inter-rater reliability (IRR) was poor at 30 and 90 degrees for both the subjective rater score and the measured AP laxity in flexion (k = 018-0.22). Varus-valgus testing similarly had poor reliability. Force applied by the rater also had poor IRR.

CONCLUSION

Clinical testing of knee laxity after TKA has poor reliability between surgeons using motion analysis. It is unclear if this is from differences in examiner technique or from differences in pain or quadriceps function of the subjects. Instability after TKA should not be diagnosed strictly by clinical testing and should involve a complete clinical assessment of the patient.

Для цитирования: Mears Simon C, Severin A Cecilia, Wang Junsig, Thostenson Jeff D, Mannen Erin M, Stambough Jeffrey B, Edwards Paul K, Barnes C Lowry. Inter-Rater Reliability of Clinical Testing for Laxity After Knee Arthroplasty.. The Journal of arthroplasty. 2022. DOI: 10.1016/j.arth.2022.03.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.