DOI 10.1007/s00256-023-04485-3
Ultrasound assessment of synovitis in total knee replacements: concordance with MR imaging and joint aspiration.
Аннотация
OBJECTIVE
To determine if diagnostic ultrasound can reliably distinguish between synovial patterns of prosthetic joint infection and polymeric wear in total knee replacements.
METHODS AND
METHODS
This retrospective study was approved by our hospital IRB. Using the radiology report database, MR examinations performed within a week of diagnostic ultrasound and/or ultrasound-guided aspiration were identified. This yielded (1) 24 cases with MR and ultrasound comparisons; (2) 44 cases with MR, ultrasound, and aspiration comparisons; and (3) 92 cases with ultrasound and aspiration comparisons. The MR studies were reviewed by a musculoskeletal radiologist. The ultrasound studies were each reviewed by 2 other musculoskeletal radiologists. Each study was graded for synovial pattern indicating infection, polymeric wear, or normal/nonspecific. Agreement between the MR grader and the ultrasound graders as well as ultrasound inter-rater agreement were assessed using k statistics. Sensitivity, specificity, positive predictive value, and negative predictive value of ultrasound were calculated.
RESULTS
Agreement between ultrasound and MR imaging was fair to moderate: k of 0.27 (95% CI: 0.04, 0.50) and 0.44 (95% CI: 0.23, 0.65) for ultrasound raters 1 and 2, respectively. Inter-rater agreement between ultrasound graders 1 and 2 was moderate, with k of 0.56 (95% CI: 0.42, 0.70). Ultrasound sensitivities for infection were 0.13 and 0.09, while specificities were 0.94 and 0.98. Ultrasound sensitivities for polymeric wear were 0.38 and 0.62 with specificities of 0.90 and 0.76.
CONCLUSION
Ultrasound does not perform well in distinguishing patterns of synovitis either compared to MRI or a reference standard of aspiration/clinical follow-up.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.