MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11547-021-01339-7

Медицинская библиотека · La Radiologia medica · 2021

Weight bearing versus conventional CT for the measurement of patellar alignment and stability in patients after surgical treatment for patellar recurrent dislocation.

Lullini Giada, Belvedere Claudio, Busacca Maurizio, Moio Antonio, Leardini Alberto, Caravelli Silvio, Maccaferri Bruna, Durante Stefano, Zaffagnini Stefano, Marcheggiani Muccioli Giulio Maria

СтатьяПеревод в очереди

Аннотация

PURPOSE: To compare weight-bearing cone-beam computer tomography (CBCT) and conventional computer tomography (CT)-based measurements of patellofemoral alignment and stability in patients surgically treated for recurrent patellar dislocation. These scans implied respectively single-leg up-right posture, the knee flexed, and lower limb muscles activation, versus supine position with the knee extended.

METHODS

A total of 17 patients (11 males/6 females) after surgical reconstruction with fascia lata allograft for recurrent patellofemoral dislocation were analyzed at 60-month follow-up. Tilt and congruence angles and tibial tuberosity-trochlear groove (TT-TG) offset were measured on images obtained from CBCT and conventional CT scans by three independent and expert radiologists. Paired t tests were performed to compare measurements obtained from the two scans. Inter-rater reliability was assessed using a two-way mixed-effects model intra-class correlation coefficient (ICC).

RESULTS

Only TT-TG offset was found significantly smaller (p < 0.001) in CBCT (mean 9.9 ± 5.3 mm) than in conventional CT (mean 15.9 ± 4.9 mm) scans. ICC for tilt and congruence angles and for TT-TG offset ranged between 0.80-0.94 with measurements in CBCT scans, between 0.52 and0.78 in conventional CT.

CONCLUSION

In patients surgically treated for recurrent patellar dislocation, TT-TG offset was found overestimated with conventional CT. All measurements of patellofemoral stability and alignment were found more consistent when obtained with weight-bearing CBCT compared to conventional CT.

Для цитирования: Lullini Giada, Belvedere Claudio, Busacca Maurizio, Moio Antonio, Leardini Alberto, Caravelli Silvio, Maccaferri Bruna, Durante Stefano, Zaffagnini Stefano, Marcheggiani Muccioli Giulio Maria. Weight bearing versus conventional CT for the measurement of patellar alignment and stability in patients after surgical treatment for patellar recurrent dislocation.. La Radiologia medica. 2021. DOI: 10.1007/s11547-021-01339-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.