MedElevator Войти в исследования
← Поиск публикаций

DOI 10.31616/asj.2020.0526

Медицинская библиотека · Asian spine journal · 2021

Accuracy of Percutaneous Pedicle Screw Placement after Single-Position versus Dual-Position Insertion for Lateral Interbody Fusion and Pedicle Screw Fixation Using Fluoroscopy.

Hiyama Akihiko, Katoh Hiroyuki, Sakai Daisuke, Sato Masato, Tanaka Masahiro, Watanabe Masahiko

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Retrospective study.

PURPOSE: The purpose of this study was to compare the accuracy of percutaneous pedicle screw (PPS) placement between prone and lateral decubitus positions during lateral lumbar interbody fusion (LLIF) and to evaluate the tendency of PPS positioning based on simple computed tomography measurements with patients in the lateral decubitus position.

OVERVIEW OF LITERATURE: There is insufficient information in the literature regarding the accuracy of inserting a PPS using fluoroscopy in patients in the lateral decubitus position.

METHODS

We included 62 patients who underwent combined LLIF surgery and PPS fixation for degenerative lumbar spondylolisthesis with spinal canal stenosis. We compared the patient demographics and the accuracy of fluoroscopy-guided PPS placement between two groups: patients who remained in the lateral decubitus position for the pedicle screw fixation (single-position surgery [SPS] group) and those who were turned to the prone position (dual-position surgery [DPS] group).

RESULTS

There were 40 patients in the DPS group and 22 in the SPS group. Of the 292 PPSs, only 12 were misplaced. In other words, 280/292 screws (95.9%) were placed correctly in the pedicle's cortical shell (grade 0). PPS insertion did not cause neurological, vascular, or visceral injuries in either group. The breach rates for the DPS and SPS groups were 4.1% (grade 1, 5 screws; grade 2, 3 screws; grade 3, 0 screw) and 4.1% (grade 1, 2 screws; grade 2, 2 screws; grade 3, 0 screw), respectively. Although there were no statistically significant differences, the downside PPS had more screw malpositioning than the upside PPS.

CONCLUSIONS

We found that PPS insertion with the patient in the decubitus position under fluoroscopic guidance might be as safe and reliable a technique as PPS insertion in the prone position, with a misplacement rate similar to that previously published.

Для цитирования: Hiyama Akihiko, Katoh Hiroyuki, Sakai Daisuke, Sato Masato, Tanaka Masahiro, Watanabe Masahiko. Accuracy of Percutaneous Pedicle Screw Placement after Single-Position versus Dual-Position Insertion for Lateral Interbody Fusion and Pedicle Screw Fixation Using Fluoroscopy.. Asian spine journal. 2021. DOI: 10.31616/asj.2020.0526.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.