MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2025.107222

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2025

Biomechanical evaluation of shape-optimized CAD/CAM magnesium plates for mandibular reconstruction.

Ruf Philipp, Richthofer Kilian, Orassi Vincenzo, Steffen Claudius, Duda Georg N, Heiland Max, Checa Sara, Rendenbach Carsten

СтатьяПеревод в очереди

Аннотация

Magnesium CAD/CAM miniplates are a promising alternative to titanium plates for mandibular reconstruction. However, gas formation is an inherent part of the magnesium degradation process, and thus, the quantity of magnesium used in fixation scenarios should be limited. Previous studies described several strategies to limit material volume, such as plate thickness reduction and shape-optimization. In particular, shape-optimization has been described as a strategy to limit material volume while maintaining mechanical integrity. In consequence, the present study compared a shape-optimized CAD/CAM magnesium miniplate with standard CAD/CAM magnesium miniplates of varying thicknesses using a biomechanical finite element model. A single-segment mandibular reconstruction was chosen as the investigative scenario, evaluated under different biting tasks to assess the different plate shapes. The shape-optimized magnesium plate demonstrated similar primary fixation stability compared to standard CAD/CAM magnesium miniplates, despite having reduced plate material and surface area. Shape optimization could help minimize magnesium volume and surface area to mitigate the issue of gas formation during the degradation process in vivo while maintaining biomechanical performance comparable to common CAD/CAM miniplates.

Для цитирования: Ruf Philipp, Richthofer Kilian, Orassi Vincenzo, Steffen Claudius, Duda Georg N, Heiland Max, Checa Sara, Rendenbach Carsten. Biomechanical evaluation of shape-optimized CAD/CAM magnesium plates for mandibular reconstruction.. Journal of the mechanical behavior of biomedical materials. 2025. DOI: 10.1016/j.jmbbm.2025.107222.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.