OBJECTIVE

To promote advanced research using magnetic resonance imaging (MRI) in the diagnosis of and screening for osteoporosis by looking for correlations among the T-scores measured by dual-energy X-ray absorptiometry (DEXA), the apparent diffusion coefficient (ADC) values on diffusion-weighted imaging (DWI), and the T1-weighted signal intensity values.

MATERIALS AND

METHODS

This was a prospective study of postmenopausal women with no contraindications to MRI and no history of cancer who underwent DEXA within 30 days before or after the MRI examination. A 3.0-T scanner was used in order to acquire sagittal sequences targeting the lumbar spine.

RESULTS

Thirteen women underwent DEXA and MRI. In two cases, the MRI was discontinued early. Therefore, the final sample comprised 11 patients. The ADC values and T1-weighted signal intensity were found to be higher in patients with osteoporosis. However, among the patients > 60 years of age with osteoporosis, ADC values were lower and T1-weighted signal intensity was even higher.

CONCLUSION

It is unlikely that MRI will soon replace DEXA for the diagnostic workup of osteoporosis. Although DWI and ADC mapping are useful for understanding the pathophysiology of osteoporosis, we believe that T1-weighted sequences are more sensitive than is DWI as a means of performing a qualitative analysis of vertebral alterations.

Для цитирования: Trentadue Mirko, Sozzi Carlo, Idolazzi Luca, Lazzarini Gianluigi, Murano Riccardo Sante, Gatti Davide, Rossini Maurizio, Piovan Enrico. Magnetic resonance imaging at 3.0-T in postmenopausal osteoporosis: a prospective study and review of the literature.. Radiologia brasileira. 2022. DOI: 10.1590/0100-3984.2021.0124.