MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2023.04.041

Медицинская библиотека · The Journal of arthroplasty · 2023

Mean 16-Year Results of Total Hip Arthroplasty With Alumina Ceramic Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years or Less.

Youngman Tyler R, Verhotz Daniel R, Layon Daniel R, Parilla Frank W, Pashos Gail E, Thornton Tanner, Bendich Ilya, Clohisy John C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Highly cross-linked polyethylene (HXLPE) is a widely used bearing surface in total hip arthroplasty (THA); long-term results in young patients are limited. We previously demonstrated excellent results in HXPLE on cobalt-chrome femoral heads at 15-year mean follow-up. The purpose of the present study was to investigate polyethylene wear rates, implant survivorships, wear-related revisions, and patient-reported outcomes (PROs) in a young patient cohort who had alumina ceramic on HXPLE coupling at an average 16-year follow-up.

METHODS

This was a retrospective study of 128 hips that underwent THA with HXLPE on alumina ceramic bearings between March 1, 2004, and April 15, 2007. The patient's mean age was 38 years (range, 13 to 50). All THAs utilized HXPLE liners with alumina ceramic heads. The University of California, Los Angeles activity score and modified Harris hip scores were collected preoperatively and at each follow-up. Martell hip analysis suite was used for wear calculations.

RESULTS

At average 16 years (range, 13 to 18), aseptic revision survivorship was 93.3% and osteolysis/wear survivorship was 99.2%. The mean linear wear rate was 0.0191 mm/year and mean volumetric wear rate was 19.43 mm3/y, both of which were clinically undetectable. We observed excellent PROs with a significant increase in mean modified Harris hip scores (43.6 to 87.4, P < .0001) and the University of California, Los Angeles activity scores (4.0 to 6.0, P < .0001). There were no statistically significant differences in PROs or wear rates between ceramic and cobalt-chrome groups.

CONCLUSION

At a mean 16-year follow-up, young patients who had HXLPE on ceramic coupling had excellent wear properties, PROs, and acceptable survivorships.

Для цитирования: Youngman Tyler R, Verhotz Daniel R, Layon Daniel R, Parilla Frank W, Pashos Gail E, Thornton Tanner, Bendich Ilya, Clohisy John C. Mean 16-Year Results of Total Hip Arthroplasty With Alumina Ceramic Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years or Less.. The Journal of arthroplasty. 2023. DOI: 10.1016/j.arth.2023.04.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.