MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jor.70102

Медицинская библиотека · Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026

Load Transfer in Tibial Intramedullary Nailing: Effects of Fracture Level, Screw Configuration and Nail-Canal Clearance.

Thiesen José L M, Prado Rafael, Kojima Kodi E, Celegatti Tóride S, Mendonça Paulo de Tarso R, Roesler Carlos R M, Fancello Eduardo A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Intramedullary nails are widely recognized for their high stabilization capacity and are considered the gold standard for tibial fracture treatment. However, hardware failure, especially of distal screws, is frequently reported, especially in cases involving distal fractures. Although various experimental studies explore screw configurations, few quantify the mechanical loads acting on individual screws at different fracture locations. This study numerically evaluates two fixation systems: one with four screws and another with five, including an additional distal screw (DS3). The results show that the fifth screw significantly reduces von Mises stress, especially in distal fractures, though the improvements in overall stability are less pronounced. The mechanical implications on the inclusion of a clearance between the nail and endosteal surface are assessed. The stresses in the locking screws are significantly higher when the reaming clearance is included in the simulation. Despite mechanical advantages, clinical trade-offs such as increased surgical complexity and radiation exposure must be considered.

Для цитирования: Thiesen José L M, Prado Rafael, Kojima Kodi E, Celegatti Tóride S, Mendonça Paulo de Tarso R, Roesler Carlos R M, Fancello Eduardo A. Load Transfer in Tibial Intramedullary Nailing: Effects of Fracture Level, Screw Configuration and Nail-Canal Clearance.. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2026. DOI: 10.1002/jor.70102.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.