MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-015-0856-z

Медицинская библиотека · BMC musculoskeletal disorders · 2016

Effect of three remplissage techniques on tendon coverage and shoulder kinematics: a navigated robotic biomechanical study.

Tan Chung Hui James, Saier Tim, von Deimling Constantin, Martetschläger Frank, Minzlaff Philipp, Feucht Matthias J, Martinez Horazio, Braun Sepp, Imhoff Andreas B, Burgkart Rainer

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In addition to Bankart repair engaging Hill-Sachs defects in glenohumeral instability have been treated successfully with remplissage procedure. The purpose of this study was to compare three remplissage techniques regarding (I) ability of preventing Hill-Sachs defect from engaging, (II) influence on glenohumeral rotational torque, and (III) resulting tendon coverage over the Hill-Sachs defect.

METHODS

Standardized engaging Hill-Sachs defects and Bankart lesions were created in n = 7 fresh frozen human shoulder specimens. Besides Bankart repair three remplissage techniques (T) with double anchor position in the valley of the defect zone were studied: T1, knots tied over anchors; T2, knots tied between anchors (double-pulley); T3, knotless anchors with a suture tape. A parallel position-orientation and force-moment controlled navigated roboticsystem was used to compare prevention of Hill-Sachs defect engagement and torque [Nm]. Pressure sensitive film was used to study area of infraspinatus tendon coverage over Hill-Sachs defect [%].

RESULTS

All remplissage techniques prevented engagement of the Hill-Sachs defect without showing any construct failures. Regarding humeral torque there were significant impairments observed between intact conditions and the three investigated repair techniques in 60° abduction and ≥30° external rotation (p < .04). There was no significant difference in torque between intervention groups (n.s.). With a mean coverage of 26.8 % over the defect zone the knotless suture tape technique (T3) significantly improved area of soft tissue coverage compared to the other techniques (p = .03).

CONCLUSION

All remplissage techniques prevented engagement of the Hill Sachs defect. With high abduction and external rotation ≥30° all techniques showed significant higher humeral torque compared to the intact specimens, while there was not one technique superior over the others. The suture tape technique conferred the largest and most effective area of tendon coverage over the Hill-Sachs defect zone. Long-term success of the remplissage procedure can possibly be enhanced by increasing the interface area of tendon coverage over the Hill-Sachs defect. Clinical studies will be necessary to proof potential benefits for clinical outcome.

Для цитирования: Tan Chung Hui James, Saier Tim, von Deimling Constantin, Martetschläger Frank, Minzlaff Philipp, Feucht Matthias J, Martinez Horazio, Braun Sepp, Imhoff Andreas B, Burgkart Rainer. Effect of three remplissage techniques on tendon coverage and shoulder kinematics: a navigated robotic biomechanical study.. BMC musculoskeletal disorders. 2016. DOI: 10.1186/s12891-015-0856-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.