MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00264-023-05705-0

Медицинская библиотека · International orthopaedics · 2023

Revision total hip arthroplasty by a ceramic bearing surface after a third- and fourth-generation ceramic head or liner fracture.

Marmor Simon, Yaacoub Jean-Jacques, Aubert Thomas, Graff Wilfrid, Mouton Antoine, Le Strat Vincent, Lhotellier Luc

СтатьяПеревод в очереди

Аннотация

PURPOSE: Although rare, fractures of ceramic components are difficult to revise, mainly due to the presence of residual ceramic debris that can cause catastrophic wear of the replacement components. Modern ceramic-on-ceramic bearings are suggested to improve outcomes of revision total hip arthroplasty (THA) for ceramic fractures. However, there are few published reports of mid-term outcomes of revision THA using ceramic-on-ceramic bearings. We evaluated clinical and radiographic outcomes of 10 patients who received ceramic-on-ceramic bearings during revision THA for ceramic fractures.

METHODS

All patients but one received fourth-generation Biolox Delta bearings. Clinical evaluation was performed using the Harris hip score at latest follow-up, and all patients received a radiographic evaluation to analyze the fixation of the acetabular cup and of the femoral stem. Osteolytic lesions and the presence of ceramic debris were noted.

RESULTS

After a mean follow-up of 8.0 years, there were no complications or implant failures, and all patients reported satisfaction with their implant. The average Harris hip score was 90.6. There was neither osteolysis nor loosening, but despite our extensive synovial debridement, ceramic debris was noted in the radiographs of five patients (50%).

CONCLUSION

We report excellent mid-term outcomes, with no implant failures after eight years despite ceramic debris being found in a significant proportion of patients. We conclude that modern ceramic-on-ceramic bearings are an advantageous option for the revision of THA due to the fracture of initial ceramic components.

Для цитирования: Marmor Simon, Yaacoub Jean-Jacques, Aubert Thomas, Graff Wilfrid, Mouton Antoine, Le Strat Vincent, Lhotellier Luc. Revision total hip arthroplasty by a ceramic bearing surface after a third- and fourth-generation ceramic head or liner fracture.. International orthopaedics. 2023. DOI: 10.1007/s00264-023-05705-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.